A N N E X E
| PRINCIPALE VILLE DESSERVIE | SITE | ALTITUDE de l'antenne (a) | PAR MAX (b) | CANAL/POLARISATION |
|---|---|---|---|---|
| ALLANCHE | Chavanon | 1 284 m | 681 mW (1) | 60 H |
| ALLEGRE | Châteauneuf | 1 035 m | 360 mW (2) | 60 H |
| AMBERT | Bunangues | 1 043 m | 58 W (3) | 25 H |
| ANTIGNAC | Puy de Vignonet | 607 m | 798 mW (4) | 54 H |
| ARLEMPDES | Le Rias | 1 082 m | 1 W (5) | 42 H |
| AUREC-SUR-LOIRE | Pied | 727 m | 1 W (6) | 22 H |
| AURILLAC | Coissy | 664 m | 2 W (7) | 54 V |
| AURILLAC | Caussac | 767 m | 15 W (8) | 54 H |
| AUZAT-SUR-ALLIER | La Combelle | 488 m | 390 mW (9) | 25 H |
| AUZON | Nord Est | 643 m | 600 mW (10) | 25 H |
| BEAUZAC | Grosse Pierre | 585 m | 130 mW (11) | 60 H |
| BELLERIVE-SUR-ALLIER | Cusset | 355 m | 60 W (12) | 33 H |
| BILLOM | Sablière de Barbarade | 440 m | 500 mW (13) | 25 H |
| BLESLE | La Chaud de la Rodde | 697 m | 500 mW (14) | 25 H |
| BORT-LES-ORGUES | Plateau de Bort 2 | 804 m | 30 W (15) | 38 H |
| BRIVES-CHARENSAC | Le Breuil-de-Doue | 679 m | 1 W (16) | 60 H |
| CHABRELOCHE | Pardillières | 842 m | 620 mW (17) | 25 H |
| CHADRAC | Le Monteil | 680 m | 600 mW (18) | 60 H |
| CHAMPEIX | La Croix du Bonhomme | 677 m | 4 W (19) | 25 H |
| CHAMPS-SUR-TARENTAINE | Perol | 686 m | 730 mW (20) | 54 H |
| CHANTEUGES | Saint-Julien des Chazes | 783 m | 1 W (21) | 25 H |
| CHATELGUYON | Puy de Creta | 511 m | 340 mW (22) | 25 H |
| CHAUDES-AIGUES | Le Couffour | 958 m | 210 mW (23) | 60 H |
| CLERMONT-FERRAND | Puy de Dôme | 1 543 m | 50 kW (24) | 25 H |
| CLERMONT-FERRAND - ROYAT | Puy de Grave Noire | 867 m | 11 W (25) | 25 H |
| COLLANDRES | Puy Vendrier | 1 061 m | 761 mW (26) | 54 H |
| COMBRONDE | Pierre Longue | 427 m | 470 mW (27) | 25 H |
| CONDAT | Vezolet | 1 067 m | 2 W (28) | 54 H |
| COUBON 1 | Poinsac | 887 m | 1 W (29) | 60 H |
| COUBON 2 | Arsac-en-Velay | 737 m | 360 mW (30) | 58 V |
| COURPIERE | Le Bouchet | 424 m | 2 W (31) | 25 H |
| CRANDELLE | Naucelles-Reilhac | 645 m | 600 mW (32) | 54 V |
| CRAPONNE-SUR-ARZON | La Ratille | 988 m | 490 mW (33) | 60 H |
| DIENNE | Laqueille | 1 300 m | 1 W (34) | 60 H |
| DUNIERES | La Tour | 971 m | 1 W (35) | 60 H |
| FERRIERES-SAINT-MARY | La Chau | 1 036 m | 610 mW (36) | 25 H |
| GIOU-DE-MAMOU | Lavinhe | 845 m | 500 mW (37) | 54 V |
| JOB | La Halle | 960 m | 3 W (38) | 23 H |
| JOSAT | Chabestrat | 981 m | 800 mW (39) | 25 H |
| JUSSAC | Le Cruqui de Cabi | 769 m | 7 W (40) | 54 H |
| LA BOURBOULE 1 | Puy de Prechonnet | 936 m | 30 W (41) | 25 H |
| LA BOURBOULE 2 | Bois de Charlannes | 1 181 m | 5 W (42) | 25 H |
| LA MONNERIE-LE-MONTEL | Solières | 654 m | 480 mW (43) | 25 H |
| LACHAPELLE GRAILLOUSE | Vente | 1 224 m | 3 W (44) | 29 H |
| LANGEAC | Volmadet | 838 m | 20 W (45) | 25 H |
| LAPRUGNE | Le Calvaire-Itas | 1 020 m | 4 W (46) | 25 H |
| LAROQUEBROU | Le Château | 603 m | 1 W (47) | 54 H |
| LAROQUEVIEILLE | Tremoux | 930 m | 3 W (48) | 54 H |
| LAVOUTE-CHILHAC | Saint-Cirgues-Soulhac | 724 m | 780 mW (49) | 23 H |
| LAVOUTE-SUR-LOIRE | Chaspinhac | 934 m | 4 W (50) | 60 H |
| LE CHAMBON-SUR-LIGNON 1 | Rousse | 1 030 m | 1 W (51) | 29 H |
| LE CHAMBON-SUR-LIGNON 2 | Romieres | 1 071 m | 350 mW (52) | 29 H |
| LE CLAUX | Pierre Grosse | 1 244 m | 580 mW (53) | 42 H |
| LE MONASTIER-SUR-GAZEILLE | Le Mont | 1 004 m | 480 mW (54) | 60 H |
| LE PUY-EN-VELAY | Mont Denise | 928 m | 250 W (55) | 51 H |
| LE PUY-EN-VELAY | Roche Arnaud | 818 m | 2 W (56) | 60 H |
| LE PUY-EN-VELAY | Saint-Jean-de-Nay | 1 296 m | 4 kW (57) | 60 H |
| MADIC | Champagnac | 556 m | 420 mW (58) | 54 H |
| MALREVERS | Suc de Jalet | 830 m | 600 mW (59) | 60 H |
| MANDAILLES | Saint-Julien de Jordanne | 1 097 m | 500 mW (60) | 54 H |
| MASSIAC | Plateau de Chalet | 704 m | 2 W (61) | 25 H |
| MAURS | Ferrières | 443 m | 2 W (62) | 54 H |
| MAZEYRAT-D'ALLIER | Nozeyrolles (est Reilhac) | 627 m | 400 mW (63) | 25 H |
| MENET | Puy-de-Menoire | 899 m | 650 mW (64) | 58 H |
| MONISTROL-D'ALLIER | Douchanez | 947 m | 3 W (65) | 36 H |
| MONISTROL-SUR-LOIRE 1 | Bas en Basset | 770 m | 20 W (66) | 24 H |
| MONT-DORE | Ferme de l'Angle | 1 300 m | 1 W (67) | 21 H |
| MONTLUÇON 1 | Quinssaines | 459 m | 76 W (68) | 25 H |
| MONTLUÇON 2 | Marignon | 378 m | 120 W (69) | 21 H |
| MONTREGARD | La Berthe | 1 143 m | 140 W (70) | 60 H |
| MONTSALVY | Les Granges | 716 m | 14 W (71) | 54 H |
| MURAT | Cheylanes | 1 141 m | 2 W (72) | 60 H |
| NEUSSARGUES-MOISSAC 1 | Montlouby | 1 192 m | 2 W (73) | 60 H |
| NEUSSARGUES-MOISSAC 2 | Route D 23 | 853 m | 320 mW (74) | 42 H |
| NEUVEGLISE | Les Arbres Ventals | 1 035 m | 300 mW (75) | 60 H |
| ORBEIL | Le Chauffour | 496 m | 1 W (76) | 25 V |
| ORCET | Les Queuilles | 482 m | 1 W (77) | 25 H |
| PERRIER | Puy de Mercœur | 529 m | 15 W (78) | 25 H |
| PIERREFORT | Le Monteil | 1 004 m | 200 mW (79) | 54 H |
| PLEAUX | Arnac | 648 m | 2 W (80) | 54 H |
| PUY-DE-SAINT-ROMAIN | Mirefleurs | 595 m | 100 W (81) | 25 H |
| RAULHAC | Lacamp | 928 m | 1 W (82) | 54 V |
| RETOURNAC | Orcier | 731 m | 4 W (83) | 60 H |
| RIOM-ES-MONTAGNES 1 | Apchon - Le Gros Mont | 1 169 m | 32 W (84) | 54 H |
| RIOM-ES-MONTAGNES 2 | Côte de la Gorce | 976 m | 1 W (85) | 54 H |
| RIOTORD | Sarcenas | 996 m | 3 W (86) | 60 H |
| ROMAGNAT | Puy Blanc | 514 m | 1 W (87) | 25 H |
| ROSIERES | La Petite Plaine | 808 m | 2 W (88) | 60 H |
| SANSAC-DE-MARMIESSE | Saint-Mamet-la-Salvetat | 691 m | 700 mW (89) | 54 H |
| SEGUR-LES-VILLAS | Vial | 1 201 m | 430 mW (90) | 25 H |
| SAINT-AMANT-ROCHE-SAVINE | Roche Savine | 1 090 m | 1 W (91) | 25 V |
| SAINT-ARCONS-DE-BARGES | Barges | 1 175 m | 2 W (92) | 42 V |
| SAINT-CERNIN 1 | La Tranchée | 766 m | 1 W (93) | 54 H |
| SAINT-CERNIN 2 | La Croix Saint-Pierre | 866 m | 2 W (94) | 54 V |
| SAINT-DIDIER-EN-VELAY | La Seauve-sur-Semene | 888 m | 1 W (95) | 60 H |
| SAINT-ELOY-LES-MINES | Puy Laroux | 649 m | 5 W (96) | 25 H |
| SAINT-ETIENNE-LARDEYROL | Montchouvet | 936 m | 791 mW (97) | 60 H |
| SAINT-FLOUR | Montafe | 1 166 m | 1,8 kW (98) | 60 H |
| SAINT-FLOUR 2 | Place des Roches | 892 m | 410 mW (99) | 60 H |
| SAINT-GERMAIN-LAPRADE 1 | Fay | 748 m | 1 W (100) | 51 H |
| SAINT-GERMAIN-LAPRADE 2 | Lantriac | 784 m | 630 mW (101) | 60 H |
| SAINT-GERMAIN-LAPRADE 3 | Le Fiou | 748 m | 400 mW (102) | 60 H |
| SAINT-JACQUES-LES-BLATS | Pas des Alpins | 1 792 m | 1 W (103) | 25 H |
| SAINT-JUST-EN-CHEVALET | Champoly-Bois d'Urfe | 977 m | 18 W (104) | 45 H |
| SAINT-JUST-MALMONT | La Ratelière | 898 m | 2 W (105) | 60 H |
| SAINT-JUST-SAINT-RAMBERT | Le Bruyat | 454 m | 2 W (106) | 34 H |
| SAINT-LAURENT-CHABREUGES | Brioude | 561 m | 370 mW (107) | 25 H |
| SAINT-MARTIN-SOUS-VIGOUROUX | Paulhenc | 953 m | 1 W (108) | 54 H |
| SAINT-MARTIN-VALMEROUX | La Croix de Jallenc | 777 m | 200 mW (109) | 54 H |
| SAINT-NECTAIRE | Puy de Mazeyres | 937 m | 20 W (110) | 25 H |
| SAINT-PAUL (15) | Les Cotes de Laubenie | 1 037 m | 2 W (111) | 54 H |
| SAINT-REMY-DE-CHAUDES-AIGUES | La Roche Canilhac | 1 134 m | 2 W (112) | 60 H |
| SAINT-SIMON | Montagne du Peintre | 896 m | 1 W (113) | 54 H |
| SAINT-URCIZE | Rignac | 1 216 m | 550 mW (114) | 60 H |
| TENCE | Peyrebrousson | 930 m | 1.2 W (115) | 60 H |
| THIERS | Pont Bas | 551 m | 3 W (116) | 25 H |
| THIEZAC 1 | Lescure | 971 m | 400 mW (117) | 58 H |
| VELZIC | Lacostes | 992 m | 1 W (118) | 54 H |
| VERTAIZON | Ancienne carrière au sud | 438 m | 929 mW (119) | 25 H |
| VERTOLAYE | Ressoncles | 778 m | 450 mW (120) | 25 H |
| VEYRE MONTON | Soulasse | 538 m | 2 W (121) | 25 V |
| VEZAC | Brouzac | 793 m | 800 mW (122) | 54 H |
| VIC-SUR-CERE 1 | Les Huttes | 967 m | 15 W (123) | 54 H |
| VIC-SUR-CERE 2 | Daisses | 733 m | 2 W (124) | 54 H |
| VILLENEUVE-D'ALLIER | Saint-Ilpize | 664 m | 921 mW (125) | 25 H |
| VIVEROLS | Les Penderies | 1 065 m | 11 W (126) | 60 H |
| VOLVIC | Rue des Chanaux | 505 m | 5 W (127) | 25 V |
| VOREY | Sanimaud | 693 m | 410 mW (128) | 58 H |
| YDES | La Butte | 578 m | 740 mW (129) | 54 H |
| YSSINGEAUX | Pied de la Roue | 946 m | 430 mW (130) | 60 H |
| (a) L'altitude de l'antenne est à respecter à plus ou moins 5 m. (b) La PAR minimale correspond à la PAR maximale diminuée des valeurs d'atténuation dans les différents azimuts figurant dans les tableaux de limitation du rayonnement dans le plan horizontal ci-dessous. | ||||
1. Le bénéficiaire est tenu de communiquer au CSA les informations suivantes dont il attestera l'exactitude :
Information communiquée dans un délai de 1 mois après la mise en service :
― compte rendu exhaustif de réalisation des synchronisations des plaques isofréquences.
Informations communiquées sans délai si elles sont disponibles :
― diagramme de rayonnement mesuré ;
― offset mis en place ;
― paramètres de modulation utilisés.
Cese informations sont exigibles sur demande expresse du conseil.
2. Dans le cas où les informations suivantes seraient modifiées par la suite, le bénéficiaire communique au CSA une version actualisée dans un délai d'un mois :
― descriptif technique de l'installation (type et puissance nominale de l'émetteur, système d'antennes...) ;
― PAR maximale et diagramme de rayonnement théorique (H et V) ;
― date de mise en service ;
― paramètres de modulation utilisés ;
― compte rendu exhaustif de réalisation des synchronisations des plaques isofréquences.
3. Le bénéficiaire est également tenu de communiquer au CSA toutes les informations en sa possession sur la couverture de l'émetteur, en particulier les résultats des mesures de couverture effectuées dans la zone de service.
4. Si le CSA a constaté le non-respect des conditions techniques de l'autorisation, le bénéficiaire est tenu de faire procéder par un organisme agréé à une vérification de la conformité de son installation aux prescriptions figurant dans l'annexe technique de l'autorisation. Le bénéficiaire transmettra au CSA les résultats de cette vérification.
(1) Limitation du rayonnement dans le plan horizontal :
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 22 | 180 | 6 | 270 | 8 |
| 10 | 22 | 100 | 22 | 190 | 3 | 280 | 12 |
| 20 | 22 | 110 | 22 | 200 | 1 | 290 | 19 |
| 30 | 22 | 120 | 22 | 210 | 0 | 300 | 20 |
| 40 | 22 | 130 | 22 | 220 | 0 | 310 | 22 |
| 50 | 22 | 140 | 20 | 230 | 0 | 320 | 21 |
| 60 | 22 | 150 | 18 | 240 | 1 | 330 | 21 |
| 70 | 22 | 160 | 12 | 250 | 3 | 340 | 21 |
| 80 | 22 | 170 | 8 | 260 | 6 | 350 | 21 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 18 | 90 | 20 | 180 | 20 | 270 | 2 |
| 10 | 20 | 100 | 20 | 190 | 20 | 280 | 0 |
| 20 | 20 | 110 | 20 | 200 | 20 | 290 | 0 |
| 30 | 20 | 120 | 20 | 210 | 20 | 300 | 0 |
| 40 | 20 | 130 | 20 | 220 | 15 | 310 | 1 |
| 50 | 20 | 140 | 20 | 230 | 12 | 320 | 3 |
| 60 | 20 | 150 | 20 | 240 | 8 | 330 | 5 |
| 70 | 20 | 160 | 20 | 250 | 5 | 340 | 8 |
| 80 | 20 | 170 | 20 | 260 | 3 | 350 | 12 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 25 | 90 | 25 | 180 | 3 | 270 | 11 |
| 10 | 25 | 100 | 25 | 190 | 2 | 280 | 16 |
| 20 | 25 | 110 | 25 | 200 | 1 | 290 | 18 |
| 30 | 25 | 120 | 20 | 210 | 0 | 300 | 20 |
| 40 | 25 | 130 | 18 | 220 | 1 | 310 | 25 |
| 50 | 25 | 140 | 15 | 230 | 2 | 320 | 25 |
| 60 | 25 | 150 | 11 | 240 | 3 | 330 | 25 |
| 70 | 25 | 160 | 8 | 250 | 6 | 340 | 25 |
| 80 | 25 | 170 | 5 | 260 | 8 | 350 | 25 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 0 | 180 | 23 | 270 | 23 |
| 10 | 16 | 100 | 1 | 190 | 25 | 280 | 23 |
| 20 | 13 | 110 | 2 | 200 | 25 | 290 | 23 |
| 30 | 10 | 120 | 4 | 210 | 23 | 300 | 23 |
| 40 | 7 | 130 | 7 | 220 | 23 | 310 | 23 |
| 50 | 4 | 140 | 9 | 230 | 23 | 320 | 23 |
| 60 | 2 | 150 | 12 | 240 | 23 | 330 | 24 |
| 70 | 1 | 160 | 15 | 250 | 23 | 340 | 24 |
| 80 | 0 | 170 | 20 | 260 | 23 | 350 | 25 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 1 | 180 | 20 | 270 | 20 |
| 10 | 2 | 100 | 1 | 190 | 20 | 280 | 20 |
| 20 | 2 | 110 | 2 | 200 | 20 | 290 | 17 |
| 30 | 1 | 120 | 3 | 210 | 20 | 300 | 11 |
| 40 | 0 | 130 | 5 | 220 | 20 | 310 | 8 |
| 50 | 0 | 140 | 8 | 230 | 20 | 320 | 5 |
| 60 | 1 | 150 | 11 | 240 | 20 | 330 | 3 |
| 70 | 2 | 160 | 17 | 250 | 20 | 340 | 2 |
| 80 | 2 | 170 | 20 | 260 | 20 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 20 | 270 | 1 |
| 10 | 20 | 100 | 20 | 190 | 14 | 280 | 2 |
| 20 | 20 | 110 | 20 | 200 | 10 | 290 | 4 |
| 30 | 20 | 120 | 20 | 210 | 6 | 300 | 6 |
| 40 | 20 | 130 | 20 | 220 | 4 | 310 | 10 |
| 50 | 20 | 140 | 20 | 230 | 2 | 320 | 14 |
| 60 | 20 | 150 | 20 | 240 | 1 | 330 | 20 |
| 70 | 20 | 160 | 20 | 250 | 0 | 340 | 20 |
| 80 | 20 | 170 | 20 | 260 | 0 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 23 | 90 | 23 | 180 | 3 | 270 | 12 |
| 10 | 23 | 100 | 22 | 190 | 2 | 280 | 16 |
| 20 | 23 | 110 | 21 | 200 | 0 | 290 | 19 |
| 30 | 23 | 120 | 20 | 210 | 0 | 300 | 20 |
| 40 | 23 | 130 | 19 | 220 | 0 | 310 | 21 |
| 50 | 23 | 140 | 16 | 230 | 2 | 320 | 23 |
| 60 | 23 | 150 | 12 | 240 | 3 | 330 | 23 |
| 70 | 23 | 160 | 8 | 250 | 6 | 340 | 23 |
| 80 | 23 | 170 | 6 | 260 | 8 | 350 | 23 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 0 | 180 | 1 | 270 | 0 |
| 10 | 1 | 100 | 1 | 190 | 2 | 280 | 1 |
| 20 | 3 | 110 | 2 | 200 | 3 | 290 | 3 |
| 30 | 3 | 120 | 2 | 210 | 4 | 300 | 2 |
| 40 | 1 | 130 | 3 | 220 | 4 | 310 | 0 |
| 50 | 0 | 140 | 4 | 230 | 3 | 320 | 0 |
| 60 | 2 | 150 | 4 | 240 | 2 | 330 | 2 |
| 70 | 2 | 160 | 3 | 250 | 1 | 340 | 2 |
| 80 | 1 | 170 | 2 | 260 | 1 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 8 | 180 | 20 | 270 | 6 |
| 10 | 1 | 100 | 12 | 190 | 24 | 280 | 3 |
| 20 | 1 | 110 | 16 | 200 | 25 | 290 | 2 |
| 30 | 1 | 120 | 19 | 210 | 20 | 300 | 1 |
| 40 | 0 | 130 | 19 | 220 | 20 | 310 | 0 |
| 50 | 1 | 140 | 20 | 230 | 18 | 320 | 1 |
| 60 | 2 | 150 | 22 | 240 | 16 | 330 | 2 |
| 70 | 4 | 160 | 23 | 250 | 11 | 340 | 1 |
| 80 | 6 | 170 | 20 | 260 | 8 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 11 | 270 | 3 |
| 10 | 20 | 100 | 20 | 190 | 8 | 280 | 5 |
| 20 | 20 | 110 | 20 | 200 | 5 | 290 | 8 |
| 30 | 20 | 120 | 20 | 210 | 3 | 300 | 11 |
| 40 | 20 | 130 | 20 | 220 | 1 | 310 | 16 |
| 50 | 20 | 140 | 20 | 230 | 0 | 320 | 20 |
| 60 | 20 | 150 | 20 | 240 | 0 | 330 | 20 |
| 70 | 20 | 160 | 20 | 250 | 0 | 340 | 20 |
| 80 | 20 | 170 | 16 | 260 | 1 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 25 | 90 | 24 | 180 | 5 | 270 | 8 |
| 10 | 25 | 100 | 23 | 190 | 3 | 280 | 11 |
| 20 | 23 | 110 | 24 | 200 | 1 | 290 | 15 |
| 30 | 20 | 120 | 25 | 210 | 0 | 300 | 19 |
| 40 | 19 | 130 | 25 | 220 | 0 | 310 | 22 |
| 50 | 20 | 140 | 20 | 230 | 0 | 320 | 25 |
| 60 | 22 | 150 | 16 | 240 | 1 | 330 | 24 |
| 70 | 25 | 160 | 11 | 250 | 3 | 340 | 23 |
| 80 | 25 | 170 | 7 | 260 | 5 | 350 | 23 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 22 | 90 | 12 | 180 | 0 | 270 | 8 |
| 10 | 22 | 100 | 8 | 190 | 0 | 280 | 13 |
| 20 | 25 | 110 | 6 | 200 | 1 | 290 | 17 |
| 30 | 25 | 120 | 3 | 210 | 2 | 300 | 20 |
| 40 | 20 | 130 | 2 | 220 | 1 | 310 | 20 |
| 50 | 20 | 140 | 1 | 230 | 1 | 320 | 19 |
| 60 | 20 | 150 | 2 | 240 | 2 | 330 | 20 |
| 70 | 20 | 160 | 2 | 250 | 4 | 340 | 22 |
| 80 | 16 | 170 | 1 | 260 | 6 | 350 | 22 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 25 | 180 | 30 | 270 | 8 |
| 10 | 5 | 100 | 25 | 190 | 27 | 280 | 6 |
| 20 | 8 | 110 | 25 | 200 | 25 | 290 | 4 |
| 30 | 11 | 120 | 30 | 210 | 25 | 300 | 2 |
| 40 | 16 | 130 | 25 | 220 | 25 | 310 | 1 |
| 50 | 20 | 140 | 20 | 230 | 26 | 320 | 0 |
| 60 | 27 | 150 | 20 | 240 | 20 | 330 | 0 |
| 70 | 26 | 160 | 20 | 250 | 18 | 340 | 0 |
| 80 | 25 | 170 | 25 | 260 | 12 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 10 | 90 | 20 | 180 | 6 | 270 | 1 |
| 10 | 15 | 100 | 20 | 190 | 4 | 280 | 1 |
| 20 | 19 | 110 | 20 | 200 | 3 | 290 | 0 |
| 30 | 20 | 120 | 20 | 210 | 3 | 300 | 0 |
| 40 | 20 | 130 | 20 | 220 | 4 | 310 | 0 |
| 50 | 20 | 140 | 18 | 230 | 4 | 320 | 1 |
| 60 | 20 | 150 | 14 | 240 | 3 | 330 | 3 |
| 70 | 20 | 160 | 10 | 250 | 1 | 340 | 5 |
| 80 | 20 | 170 | 8 | 260 | 1 | 350 | 8 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 4 | 90 | 0 | 180 | 1 | 270 | 10 |
| 10 | 3 | 100 | 1 | 190 | 1 | 280 | 20 |
| 20 | 1 | 110 | 1 | 200 | 0 | 290 | 20 |
| 30 | 0 | 120 | 0 | 210 | 0 | 300 | 18 |
| 40 | 0 | 130 | 1 | 220 | 0 | 310 | 16 |
| 50 | 1 | 140 | 2 | 230 | 2 | 320 | 16 |
| 60 | 1 | 150 | 1 | 240 | 4 | 330 | 18 |
| 70 | 1 | 160 | 0 | 250 | 5 | 340 | 10 |
| 80 | 0 | 170 | 0 | 260 | 7 | 350 | 6 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 0 | 270 | 20 |
| 10 | 20 | 100 | 20 | 190 | 0 | 280 | 20 |
| 20 | 20 | 110 | 16 | 200 | 1 | 290 | 20 |
| 30 | 20 | 120 | 12 | 210 | 3 | 300 | 20 |
| 40 | 20 | 130 | 8 | 220 | 5 | 310 | 20 |
| 50 | 20 | 140 | 5 | 230 | 8 | 320 | 20 |
| 60 | 20 | 150 | 3 | 240 | 12 | 330 | 20 |
| 70 | 20 | 160 | 2 | 250 | 18 | 340 | 20 |
| 80 | 20 | 170 | 0 | 260 | 20 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 10 | 180 | 1 | 270 | 2 |
| 10 | 20 | 100 | 7 | 190 | 1 | 280 | 4 |
| 20 | 20 | 110 | 5 | 200 | 0 | 290 | 6 |
| 30 | 20 | 120 | 3 | 210 | 1 | 300 | 8 |
| 40 | 20 | 130 | 1 | 220 | 1 | 310 | 11 |
| 50 | 20 | 140 | 0 | 230 | 1 | 320 | 15 |
| 60 | 20 | 150 | 0 | 240 | 0 | 330 | 18 |
| 70 | 18 | 160 | 1 | 250 | 0 | 340 | 20 |
| 80 | 13 | 170 | 2 | 260 | 1 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 23 | 90 | 23 | 180 | 5 | 270 | 8 |
| 10 | 25 | 100 | 24 | 190 | 3 | 280 | 10 |
| 20 | 23 | 110 | 23 | 200 | 1 | 290 | 15 |
| 30 | 22 | 120 | 25 | 210 | 0 | 300 | 20 |
| 40 | 22 | 130 | 23 | 220 | 0 | 310 | 25 |
| 50 | 23 | 140 | 20 | 230 | 0 | 320 | 25 |
| 60 | 25 | 150 | 15 | 240 | 1 | 330 | 23 |
| 70 | 24 | 160 | 10 | 250 | 3 | 340 | 23 |
| 80 | 23 | 170 | 8 | 260 | 5 | 350 | 24 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 5 | 180 | 18 | 270 | 3 |
| 10 | 4 | 100 | 7 | 190 | 20 | 280 | 1 |
| 20 | 3 | 110 | 12 | 200 | 25 | 290 | 0 |
| 30 | 1 | 120 | 18 | 210 | 30 | 300 | 0 |
| 40 | 0 | 130 | 25 | 220 | 25 | 310 | 0 |
| 50 | 0 | 140 | 30 | 230 | 18 | 320 | 1 |
| 60 | 0 | 150 | 30 | 240 | 11 | 330 | 3 |
| 70 | 1 | 160 | 20 | 250 | 7 | 340 | 4 |
| 80 | 3 | 170 | 18 | 260 | 5 | 350 | 3 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 18 | 90 | 17 | 180 | 1 | 270 | 1 |
| 10 | 20 | 100 | 13 | 190 | 1 | 280 | 2 |
| 20 | 18 | 110 | 8 | 200 | 1 | 290 | 4 |
| 30 | 17 | 120 | 6 | 210 | 0 | 300 | 6 |
| 40 | 20 | 130 | 3 | 220 | 0 | 310 | 9 |
| 50 | 25 | 140 | 2 | 230 | 1 | 320 | 15 |
| 60 | 20 | 150 | 1 | 240 | 1 | 330 | 18 |
| 70 | 19 | 160 | 0 | 250 | 0 | 340 | 19 |
| 80 | 18 | 170 | 1 | 260 | 0 | 350 | 17 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 8 | 90 | 27 | 180 | 27 | 270 | 5 |
| 10 | 10 | 100 | 30 | 190 | 25 | 280 | 3 |
| 20 | 15 | 110 | 27 | 200 | 27 | 290 | 1 |
| 30 | 20 | 120 | 25 | 210 | 30 | 300 | 0 |
| 40 | 30 | 130 | 20 | 220 | 25 | 310 | 0 |
| 50 | 27 | 140 | 20 | 230 | 20 | 320 | 0 |
| 60 | 25 | 150 | 25 | 240 | 15 | 330 | 1 |
| 70 | 25 | 160 | 27 | 250 | 10 | 340 | 3 |
| 80 | 25 | 170 | 30 | 260 | 8 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 8 | 90 | 3 | 180 | 0 | 270 | 20 |
| 10 | 6 | 100 | 6 | 190 | 0 | 280 | 20 |
| 20 | 4 | 110 | 7 | 200 | 1 | 290 | 20 |
| 30 | 2 | 120 | 5 | 210 | 2 | 300 | 20 |
| 40 | 1 | 130 | 5 | 220 | 4 | 310 | 20 |
| 50 | 0 | 140 | 5 | 230 | 6 | 320 | 20 |
| 60 | 0 | 150 | 3 | 240 | 9 | 330 | 20 |
| 70 | 0 | 160 | 1 | 250 | 15 | 340 | 20 |
| 80 | 1 | 170 | 0 | 260 | 20 | 350 | 18 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 25 | 180 | 23 | 270 | 23 |
| 10 | 0 | 100 | 24 | 190 | 23 | 280 | 23 |
| 20 | 0 | 110 | 23 | 200 | 23 | 290 | 20 |
| 30 | 2 | 120 | 22 | 210 | 23 | 300 | 17 |
| 40 | 3 | 130 | 22 | 220 | 25 | 310 | 13 |
| 50 | 6 | 140 | 22 | 230 | 23 | 320 | 8 |
| 60 | 9 | 150 | 22 | 240 | 22 | 330 | 5 |
| 70 | 15 | 160 | 23 | 250 | 22 | 340 | 3 |
| 80 | 20 | 170 | 25 | 260 | 22 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 4 | 90 | 6 | 180 | 2 | 270 | 3 |
| 10 | 2 | 100 | 6 | 190 | 4 | 280 | 3 |
| 20 | 1 | 110 | 8 | 200 | 7 | 290 | 4 |
| 30 | 0 | 120 | 4 | 210 | 8 | 300 | 6 |
| 40 | 0 | 130 | 2 | 220 | 7 | 310 | 8 |
| 50 | 1 | 140 | 1 | 230 | 9 | 320 | 9 |
| 60 | 2 | 150 | 0 | 240 | 8 | 330 | 7 |
| 70 | 4 | 160 | 0 | 250 | 5 | 340 | 9 |
| 80 | 8 | 170 | 1 | 260 | 4 | 350 | 8 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 2 | 180 | 16 | 270 | 20 |
| 10 | 0 | 100 | 1 | 190 | 20 | 280 | 20 |
| 20 | 1 | 110 | 0 | 200 | 20 | 290 | 20 |
| 30 | 2 | 120 | 1 | 210 | 20 | 300 | 17 |
| 40 | 3 | 130 | 2 | 220 | 20 | 310 | 12 |
| 50 | 1 | 140 | 5 | 230 | 20 | 320 | 9 |
| 60 | 0 | 150 | 7 | 240 | 20 | 330 | 6 |
| 70 | 1 | 160 | 9 | 250 | 20 | 340 | 4 |
| 80 | 3 | 170 | 12 | 260 | 20 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 6 | 90 | 7 | 180 | 1 | 270 | 20 |
| 10 | 3 | 100 | 7 | 190 | 3 | 280 | 20 |
| 20 | 1 | 110 | 7 | 200 | 6 | 290 | 20 |
| 30 | 0 | 120 | 6 | 210 | 10 | 300 | 20 |
| 40 | 0 | 130 | 3 | 220 | 14 | 310 | 20 |
| 50 | 1 | 140 | 2 | 230 | 20 | 320 | 20 |
| 60 | 2 | 150 | 1 | 240 | 20 | 330 | 15 |
| 70 | 4 | 160 | 0 | 250 | 20 | 340 | 12 |
| 80 | 7 | 170 | 0 | 260 | 20 | 350 | 9 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 7 | 90 | 20 | 180 | 6 | 270 | 1 |
| 10 | 9 | 100 | 20 | 190 | 3 | 280 | 1 |
| 20 | 13 | 110 | 25 | 200 | 2 | 290 | 1 |
| 30 | 17 | 120 | 25 | 210 | 1 | 300 | 1 |
| 40 | 19 | 130 | 20 | 220 | 0 | 310 | 0 |
| 50 | 20 | 140 | 18 | 230 | 1 | 320 | 0 |
| 60 | 20 | 150 | 24 | 240 | 2 | 330 | 1 |
| 70 | 25 | 160 | 10 | 250 | 2 | 340 | 3 |
| 80 | 20 | 170 | 8 | 260 | 1 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 10 | 90 | 3 | 180 | 20 | 270 | 20 |
| 10 | 7 | 100 | 5 | 190 | 20 | 280 | 20 |
| 20 | 5 | 110 | 8 | 200 | 20 | 290 | 20 |
| 30 | 3 | 120 | 10 | 210 | 20 | 300 | 20 |
| 40 | 1 | 130 | 16 | 220 | 20 | 310 | 20 |
| 50 | 0 | 140 | 20 | 230 | 20 | 320 | 20 |
| 60 | 0 | 150 | 20 | 240 | 20 | 330 | 20 |
| 70 | 0 | 160 | 20 | 250 | 20 | 340 | 20 |
| 80 | 1 | 170 | 20 | 260 | 20 | 350 | 16 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 3 | 180 | 4 | 270 | 5 |
| 10 | 1 | 100 | 2 | 190 | 3 | 280 | 3 |
| 20 | 1 | 110 | 2 | 200 | 2 | 290 | 2 |
| 30 | 1 | 120 | 3 | 210 | 4 | 300 | 4 |
| 40 | 1 | 130 | 5 | 220 | 5 | 310 | 5 |
| 50 | 0 | 140 | 5 | 230 | 4 | 320 | 4 |
| 60 | 0 | 150 | 4 | 240 | 4 | 330 | 4 |
| 70 | 1 | 160 | 5 | 250 | 4 | 340 | 5 |
| 80 | 2 | 170 | 5 | 260 | 5 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 4 | 270 | 6 |
| 10 | 20 | 100 | 20 | 190 | 2 | 280 | 9 |
| 20 | 20 | 110 | 20 | 200 | 1 | 290 | 10 |
| 30 | 20 | 120 | 19 | 210 | 0 | 300 | 14 |
| 40 | 20 | 130 | 17 | 220 | 0 | 310 | 18 |
| 50 | 20 | 140 | 15 | 230 | 0 | 320 | 20 |
| 60 | 20 | 150 | 12 | 240 | 1 | 330 | 20 |
| 70 | 20 | 160 | 9 | 250 | 2 | 340 | 20 |
| 80 | 20 | 170 | 6 | 260 | 4 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 20 | 270 | 0 |
| 10 | 20 | 100 | 20 | 190 | 18 | 280 | 1 |
| 20 | 20 | 110 | 20 | 200 | 12 | 290 | 3 |
| 30 | 20 | 120 | 20 | 210 | 9 | 300 | 5 |
| 40 | 20 | 130 | 20 | 220 | 5 | 310 | 9 |
| 50 | 20 | 140 | 20 | 230 | 3 | 320 | 12 |
| 60 | 20 | 150 | 20 | 240 | 1 | 330 | 18 |
| 70 | 20 | 160 | 20 | 250 | 0 | 340 | 20 |
| 80 | 20 | 170 | 20 | 260 | 0 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 10 | 180 | 15 | 270 | 1 |
| 10 | 20 | 100 | 10 | 190 | 12 | 280 | 3 |
| 20 | 20 | 110 | 10 | 200 | 8 | 290 | 5 |
| 30 | 17 | 120 | 11 | 210 | 5 | 300 | 8 |
| 40 | 17 | 130 | 14 | 220 | 3 | 310 | 11 |
| 50 | 16 | 140 | 21 | 230 | 1 | 320 | 16 |
| 60 | 15 | 150 | 20 | 240 | 0 | 330 | 19 |
| 70 | 12 | 160 | 17 | 250 | 0 | 340 | 19 |
| 80 | 10 | 170 | 17 | 260 | 0 | 350 | 19 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 8 | 90 | 3 | 180 | 10 | 270 | 20 |
| 10 | 8 | 100 | 5 | 190 | 11 | 280 | 15 |
| 20 | 5 | 110 | 7 | 200 | 14 | 290 | 12 |
| 30 | 3 | 120 | 10 | 210 | 18 | 300 | 10 |
| 40 | 2 | 130 | 9 | 220 | 18 | 310 | 9 |
| 50 | 0 | 140 | 8 | 230 | 15 | 320 | 9 |
| 60 | 0 | 150 | 8 | 240 | 13 | 330 | 8 |
| 70 | 0 | 160 | 9 | 250 | 14 | 340 | 8 |
| 80 | 1 | 170 | 9 | 260 | 18 | 350 | 8 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 6 | 90 | 6 | 180 | 13 | 270 | 1 |
| 10 | 4 | 100 | 9 | 190 | 13 | 280 | 2 |
| 20 | 2 | 110 | 12 | 200 | 9 | 290 | 4 |
| 30 | 1 | 120 | 12 | 210 | 6 | 300 | 6 |
| 40 | 0 | 130 | 15 | 220 | 3 | 310 | 8 |
| 50 | 0 | 140 | 20 | 230 | 1 | 320 | 8 |
| 60 | 1 | 150 | 21 | 240 | 0 | 330 | 7 |
| 70 | 1 | 160 | 20 | 250 | 0 | 340 | 8 |
| 80 | 3 | 170 | 15 | 260 | 0 | 350 | 8 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 1 | 180 | 20 | 270 | 20 |
| 10 | 1 | 100 | 2 | 190 | 20 | 280 | 20 |
| 20 | 2 | 110 | 2 | 200 | 20 | 290 | 20 |
| 30 | 2 | 120 | 4 | 210 | 20 | 300 | 19 |
| 40 | 0 | 130 | 5 | 220 | 20 | 310 | 13 |
| 50 | 0 | 140 | 8 | 230 | 20 | 320 | 8 |
| 60 | 1 | 150 | 10 | 240 | 20 | 330 | 5 |
| 70 | 2 | 160 | 14 | 250 | 20 | 340 | 4 |
| 80 | 2 | 170 | 18 | 260 | 20 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 20 | 270 | 0 |
| 10 | 20 | 100 | 20 | 190 | 20 | 280 | 1 |
| 20 | 20 | 110 | 20 | 200 | 12 | 290 | 2 |
| 30 | 20 | 120 | 20 | 210 | 10 | 300 | 4 |
| 40 | 20 | 130 | 20 | 220 | 6 | 310 | 6 |
| 50 | 20 | 140 | 20 | 230 | 4 | 320 | 10 |
| 60 | 20 | 150 | 20 | 240 | 2 | 330 | 12 |
| 70 | 20 | 160 | 20 | 250 | 1 | 340 | 19 |
| 80 | 20 | 170 | 20 | 260 | 0 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 16 | 90 | 1 | 180 | 4 | 270 | 3 |
| 10 | 15 | 100 | 1 | 190 | 2 | 280 | 3 |
| 20 | 15 | 110 | 3 | 200 | 1 | 290 | 2 |
| 30 | 13 | 120 | 4 | 210 | 1 | 300 | 2 |
| 40 | 9 | 130 | 7 | 220 | 3 | 310 | 2 |
| 50 | 6 | 140 | 7 | 230 | 3 | 320 | 3 |
| 60 | 3 | 150 | 6 | 240 | 1 | 330 | 6 |
| 70 | 3 | 160 | 8 | 250 | 0 | 340 | 8 |
| 80 | 1 | 170 | 6 | 260 | 1 | 350 | 15 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 11 | 90 | 23 | 180 | 2 | 270 | 1 |
| 10 | 14 | 100 | 24 | 190 | 1 | 280 | 1 |
| 20 | 20 | 110 | 24 | 200 | 0 | 290 | 1 |
| 30 | 24 | 120 | 20 | 210 | 0 | 300 | 0 |
| 40 | 24 | 130 | 14 | 220 | 1 | 310 | 1 |
| 50 | 24 | 140 | 11 | 230 | 1 | 320 | 2 |
| 60 | 20 | 150 | 8 | 240 | 0 | 330 | 4 |
| 70 | 19 | 160 | 6 | 250 | 0 | 340 | 6 |
| 80 | 19 | 170 | 3 | 260 | 0 | 350 | 8 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 16 | 90 | 9 | 180 | 0 | 270 | 6 |
| 10 | 16 | 100 | 6 | 190 | 0 | 280 | 9 |
| 20 | 20 | 110 | 3 | 200 | 1 | 290 | 14 |
| 30 | 20 | 120 | 1 | 210 | 2 | 300 | 20 |
| 40 | 20 | 130 | 0 | 220 | 1 | 310 | 20 |
| 50 | 20 | 140 | 0 | 230 | 0 | 320 | 20 |
| 60 | 20 | 150 | 1 | 240 | 0 | 330 | 20 |
| 70 | 19 | 160 | 2 | 250 | 1 | 340 | 20 |
| 80 | 14 | 170 | 1 | 260 | 3 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 19 | 90 | 1 | 180 | 26 | 270 | 25 |
| 10 | 13 | 100 | 2 | 190 | 25 | 280 | 25 |
| 20 | 10 | 110 | 5 | 200 | 24 | 290 | 25 |
| 30 | 7 | 120 | 7 | 210 | 24 | 300 | 24 |
| 40 | 4 | 130 | 11 | 220 | 25 | 310 | 24 |
| 50 | 2 | 140 | 15 | 230 | 25 | 320 | 24 |
| 60 | 1 | 150 | 19 | 240 | 25 | 330 | 24 |
| 70 | 0 | 160 | 24 | 250 | 25 | 340 | 24 |
| 80 | 0 | 170 | 26 | 260 | 25 | 350 | 24 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 0 | 180 | 0 | 270 | 0 |
| 10 | 0 | 100 | 1 | 190 | 0 | 280 | 0 |
| 20 | 1 | 110 | 1 | 200 | 1 | 290 | 1 |
| 30 | 1 | 120 | 1 | 210 | 1 | 300 | 1 |
| 40 | 0 | 130 | 0 | 220 | 0 | 310 | 0 |
| 50 | 0 | 140 | 0 | 230 | 0 | 320 | 0 |
| 60 | 0 | 150 | 0 | 240 | 0 | 330 | 0 |
| 70 | 1 | 160 | 1 | 250 | 1 | 340 | 1 |
| 80 | 0 | 170 | 0 | 260 | 0 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 0 | 180 | 23 | 270 | 28 |
| 10 | 1 | 100 | 1 | 190 | 23 | 280 | 18 |
| 20 | 1 | 110 | 3 | 200 | 21 | 290 | 10 |
| 30 | 0 | 120 | 5 | 210 | 19 | 300 | 8 |
| 40 | 0 | 130 | 7 | 220 | 19 | 310 | 5 |
| 50 | 1 | 140 | 11 | 230 | 23 | 320 | 3 |
| 60 | 1 | 150 | 18 | 240 | 23 | 330 | 1 |
| 70 | 1 | 160 | 23 | 250 | 23 | 340 | 0 |
| 80 | 0 | 170 | 28 | 260 | 23 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 4 | 90 | 1 | 180 | 4 | 270 | 0 |
| 10 | 2 | 100 | 2 | 190 | 6 | 280 | 1 |
| 20 | 1 | 110 | 2 | 200 | 6 | 290 | 1 |
| 30 | 0 | 120 | 2 | 210 | 4 | 300 | 1 |
| 40 | 0 | 130 | 4 | 220 | 2 | 310 | 0 |
| 50 | 0 | 140 | 5 | 230 | 2 | 320 | 1 |
| 60 | 0 | 150 | 4 | 240 | 2 | 330 | 2 |
| 70 | 0 | 160 | 4 | 250 | 1 | 340 | 4 |
| 80 | 0 | 170 | 4 | 260 | 0 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 6 | 180 | 20 | 270 | 8 |
| 10 | 0 | 100 | 9 | 190 | 20 | 280 | 5 |
| 20 | 1 | 110 | 12 | 200 | 20 | 290 | 3 |
| 30 | 1 | 120 | 15 | 210 | 20 | 300 | 2 |
| 40 | 1 | 130 | 18 | 220 | 20 | 310 | 1 |
| 50 | 0 | 140 | 18 | 230 | 18 | 320 | 0 |
| 60 | 1 | 150 | 18 | 240 | 17 | 330 | 1 |
| 70 | 2 | 160 | 20 | 250 | 15 | 340 | 2 |
| 80 | 4 | 170 | 20 | 260 | 10 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 1 | 180 | 15 | 270 | 21 |
| 10 | 0 | 100 | 0 | 190 | 20 | 280 | 20 |
| 20 | 1 | 110 | 0 | 200 | 22 | 290 | 17 |
| 30 | 2 | 120 | 1 | 210 | 25 | 300 | 12 |
| 40 | 2 | 130 | 2 | 220 | 23 | 310 | 8 |
| 50 | 1 | 140 | 4 | 230 | 20 | 320 | 6 |
| 60 | 1 | 150 | 6 | 240 | 21 | 330 | 4 |
| 70 | 1 | 160 | 8 | 250 | 25 | 340 | 2 |
| 80 | 1 | 170 | 12 | 260 | 23 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 5 | 90 | 20 | 180 | 9 | 270 | 0 |
| 10 | 8 | 100 | 20 | 190 | 5 | 280 | 0 |
| 20 | 12 | 110 | 20 | 200 | 3 | 290 | 1 |
| 30 | 17 | 120 | 20 | 210 | 1 | 300 | 2 |
| 40 | 20 | 130 | 20 | 220 | 0 | 310 | 1 |
| 50 | 20 | 140 | 20 | 230 | 0 | 320 | 0 |
| 60 | 20 | 150 | 20 | 240 | 1 | 330 | 0 |
| 70 | 20 | 160 | 18 | 250 | 2 | 340 | 1 |
| 80 | 20 | 170 | 12 | 260 | 1 | 350 | 3 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 8 | 180 | 3 | 270 | 10 |
| 10 | 15 | 100 | 7 | 190 | 5 | 280 | 12 |
| 20 | 12 | 110 | 5 | 200 | 8 | 290 | 15 |
| 30 | 10 | 120 | 3 | 210 | 9 | 300 | 18 |
| 40 | 10 | 130 | 1 | 220 | 9 | 310 | 18 |
| 50 | 9 | 140 | 0 | 230 | 9 | 320 | 16 |
| 60 | 9 | 150 | 0 | 240 | 9 | 330 | 14 |
| 70 | 9 | 160 | 0 | 250 | 9 | 340 | 14 |
| 80 | 9 | 170 | 1 | 260 | 10 | 350 | 18 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 6 | 90 | 15 | 180 | 15 | 270 | 2 |
| 10 | 5 | 100 | 15 | 190 | 10 | 280 | 3 |
| 20 | 4 | 110 | 15 | 200 | 8 | 290 | 5 |
| 30 | 5 | 120 | 15 | 210 | 5 | 300 | 8 |
| 40 | 6 | 130 | 15 | 220 | 3 | 310 | 10 |
| 50 | 7 | 140 | 15 | 230 | 2 | 320 | 14 |
| 60 | 10 | 150 | 15 | 240 | 1 | 330 | 12 |
| 70 | 12 | 160 | 15 | 250 | 0 | 340 | 10 |
| 80 | 14 | 170 | 15 | 260 | 1 | 350 | 7 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 7 | 180 | 20 | 270 | 5 |
| 10 | 1 | 100 | 10 | 190 | 20 | 280 | 3 |
| 20 | 1 | 110 | 13 | 200 | 20 | 290 | 2 |
| 30 | 1 | 120 | 16 | 210 | 20 | 300 | 1 |
| 40 | 0 | 130 | 19 | 220 | 20 | 310 | 0 |
| 50 | 0 | 140 | 20 | 230 | 18 | 320 | 1 |
| 60 | 1 | 150 | 20 | 240 | 15 | 330 | 2 |
| 70 | 3 | 160 | 20 | 250 | 10 | 340 | 2 |
| 80 | 5 | 170 | 20 | 260 | 8 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 2 | 180 | 20 | 270 | 10 |
| 10 | 1 | 100 | 4 | 190 | 20 | 280 | 8 |
| 20 | 0 | 110 | 6 | 200 | 20 | 290 | 6 |
| 30 | 1 | 120 | 8 | 210 | 20 | 300 | 4 |
| 40 | 2 | 130 | 10 | 220 | 20 | 310 | 3 |
| 50 | 2 | 140 | 14 | 230 | 20 | 320 | 1 |
| 60 | 1 | 150 | 18 | 240 | 20 | 330 | 0 |
| 70 | 0 | 160 | 20 | 250 | 20 | 340 | 1 |
| 80 | 1 | 170 | 20 | 260 | 14 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 15 | 90 | 1 | 180 | 20 | 270 | 20 |
| 10 | 10 | 100 | 3 | 190 | 20 | 280 | 20 |
| 20 | 7 | 110 | 5 | 200 | 20 | 290 | 20 |
| 30 | 5 | 120 | 7 | 210 | 20 | 300 | 20 |
| 40 | 3 | 130 | 10 | 220 | 20 | 310 | 20 |
| 50 | 1 | 140 | 16 | 230 | 20 | 320 | 20 |
| 60 | 0 | 150 | 20 | 240 | 20 | 330 | 20 |
| 70 | 0 | 160 | 20 | 250 | 20 | 340 | 20 |
| 80 | 0 | 170 | 20 | 260 | 20 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 0 | 180 | 20 | 270 | 20 |
| 10 | 2 | 100 | 1 | 190 | 20 | 280 | 20 |
| 20 | 2 | 110 | 3 | 200 | 20 | 290 | 14 |
| 30 | 1 | 120 | 6 | 210 | 16 | 300 | 10 |
| 40 | 1 | 130 | 10 | 220 | 16 | 310 | 6 |
| 50 | 2 | 140 | 14 | 230 | 20 | 320 | 3 |
| 60 | 2 | 150 | 19 | 240 | 20 | 330 | 1 |
| 70 | 1 | 160 | 20 | 250 | 20 | 340 | 0 |
| 80 | 0 | 170 | 20 | 260 | 20 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 20 | 270 | 0 |
| 10 | 20 | 100 | 20 | 190 | 20 | 280 | 0 |
| 20 | 20 | 110 | 20 | 200 | 20 | 290 | 0 |
| 30 | 20 | 120 | 20 | 210 | 16 | 300 | 1 |
| 40 | 20 | 130 | 20 | 220 | 13 | 310 | 3 |
| 50 | 20 | 140 | 20 | 230 | 8 | 320 | 5 |
| 60 | 20 | 150 | 20 | 240 | 5 | 330 | 8 |
| 70 | 20 | 160 | 20 | 250 | 3 | 340 | 11 |
| 80 | 20 | 170 | 20 | 260 | 1 | 350 | 16 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 15 | 90 | 5 | 180 | 8 | 270 | 20 |
| 10 | 14 | 100 | 3 | 190 | 9 | 280 | 22 |
| 20 | 12 | 110 | 2 | 200 | 10 | 290 | 20 |
| 30 | 12 | 120 | 0 | 210 | 10 | 300 | 17 |
| 40 | 12 | 130 | 0 | 220 | 10 | 310 | 15 |
| 50 | 11 | 140 | 0 | 230 | 10 | 320 | 15 |
| 60 | 11 | 150 | 1 | 240 | 10 | 330 | 17 |
| 70 | 10 | 160 | 3 | 250 | 12 | 340 | 19 |
| 80 | 8 | 170 | 5 | 260 | 15 | 350 | 22 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 14 | 90 | 4 | 180 | 7 | 270 | 25 |
| 10 | 12 | 100 | 2 | 190 | 7 | 280 | 25 |
| 20 | 10 | 110 | 0 | 200 | 8 | 290 | 25 |
| 30 | 9 | 120 | 0 | 210 | 10 | 300 | 25 |
| 40 | 8 | 130 | 1 | 220 | 12 | 310 | 25 |
| 50 | 7 | 140 | 2 | 230 | 14 | 320 | 25 |
| 60 | 7 | 150 | 5 | 240 | 16 | 330 | 20 |
| 70 | 8 | 160 | 9 | 250 | 17 | 340 | 16 |
| 80 | 8 | 170 | 8 | 260 | 20 | 350 | 14 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 18 | 180 | 10 | 270 | 2 |
| 10 | 0 | 100 | 26 | 190 | 8 | 280 | 5 |
| 20 | 1 | 110 | 22 | 200 | 6 | 290 | 5 |
| 30 | 3 | 120 | 18 | 210 | 4 | 300 | 2 |
| 40 | 4 | 130 | 18 | 220 | 3 | 310 | 2 |
| 50 | 6 | 140 | 22 | 230 | 1 | 320 | 5 |
| 60 | 8 | 150 | 26 | 240 | 0 | 330 | 5 |
| 70 | 10 | 160 | 18 | 250 | 0 | 340 | 2 |
| 80 | 14 | 170 | 14 | 260 | 1 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 6 | 90 | 4 | 180 | 7 | 270 | 10 |
| 10 | 8 | 100 | 3 | 190 | 8 | 280 | 9 |
| 20 | 6 | 110 | 5 | 200 | 6 | 290 | 11 |
| 30 | 2 | 120 | 4 | 210 | 9 | 300 | 10 |
| 40 | 1 | 130 | 1 | 220 | 8 | 310 | 6 |
| 50 | 0 | 140 | 0 | 230 | 6 | 320 | 6 |
| 60 | 0 | 150 | 0 | 240 | 6 | 330 | 6 |
| 70 | 1 | 160 | 1 | 250 | 7 | 340 | 8 |
| 80 | 4 | 170 | 2 | 260 | 11 | 350 | 8 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 5 | 90 | 8 | 180 | 20 | 270 | 20 |
| 10 | 3 | 100 | 10 | 190 | 20 | 280 | 20 |
| 20 | 2 | 110 | 16 | 200 | 20 | 290 | 20 |
| 30 | 1 | 120 | 20 | 210 | 20 | 300 | 20 |
| 40 | 0 | 130 | 20 | 220 | 20 | 310 | 20 |
| 50 | 1 | 140 | 20 | 230 | 20 | 320 | 19 |
| 60 | 2 | 150 | 20 | 240 | 20 | 330 | 16 |
| 70 | 3 | 160 | 20 | 250 | 20 | 340 | 10 |
| 80 | 5 | 170 | 20 | 260 | 20 | 350 | 8 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 6 | 90 | 18 | 180 | 5 | 270 | 4 |
| 10 | 8 | 100 | 18 | 190 | 2 | 280 | 5 |
| 20 | 10 | 110 | 20 | 200 | 1 | 290 | 6 |
| 30 | 13 | 120 | 25 | 210 | 0 | 300 | 5 |
| 40 | 16 | 130 | 25 | 220 | 0 | 310 | 4 |
| 50 | 20 | 140 | 20 | 230 | 0 | 320 | 3 |
| 60 | 23 | 150 | 15 | 240 | 1 | 330 | 3 |
| 70 | 25 | 160 | 10 | 250 | 3 | 340 | 4 |
| 80 | 21 | 170 | 7 | 260 | 4 | 350 | 4 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 16 | 90 | 2 | 180 | 2 | 270 | 15 |
| 10 | 11 | 100 | 4 | 190 | 1 | 280 | 20 |
| 20 | 7 | 110 | 6 | 200 | 1 | 290 | 30 |
| 30 | 5 | 120 | 8 | 210 | 0 | 300 | 25 |
| 40 | 3 | 130 | 10 | 220 | 1 | 310 | 20 |
| 50 | 1 | 140 | 10 | 230 | 2 | 320 | 18 |
| 60 | 0 | 150 | 9 | 240 | 4 | 330 | 18 |
| 70 | 0 | 160 | 6 | 250 | 7 | 340 | 20 |
| 80 | 1 | 170 | 4 | 260 | 10 | 350 | 25 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 0 | 270 | 20 |
| 10 | 20 | 100 | 20 | 190 | 0 | 280 | 20 |
| 20 | 20 | 110 | 19 | 200 | 1 | 290 | 20 |
| 30 | 20 | 120 | 14 | 210 | 2 | 300 | 20 |
| 40 | 20 | 130 | 9 | 220 | 4 | 310 | 20 |
| 50 | 20 | 140 | 6 | 230 | 6 | 320 | 20 |
| 60 | 20 | 150 | 4 | 240 | 9 | 330 | 20 |
| 70 | 20 | 160 | 2 | 250 | 13 | 340 | 20 |
| 80 | 20 | 170 | 1 | 260 | 18 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 10 | 90 | 20 | 180 | 8 | 270 | 3 |
| 10 | 11 | 100 | 16 | 190 | 7 | 280 | 5 |
| 20 | 15 | 110 | 12 | 200 | 5 | 290 | 7 |
| 30 | 20 | 120 | 10 | 210 | 3 | 300 | 9 |
| 40 | 19 | 130 | 10 | 220 | 1 | 310 | 9 |
| 50 | 15 | 140 | 9 | 230 | 0 | 320 | 9 |
| 60 | 14 | 150 | 9 | 240 | 0 | 330 | 9 |
| 70 | 15 | 160 | 8 | 250 | 0 | 340 | 9 |
| 80 | 19 | 170 | 8 | 260 | 1 | 350 | 10 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 12 | 270 | 3 |
| 10 | 20 | 100 | 20 | 190 | 9 | 280 | 5 |
| 20 | 20 | 110 | 20 | 200 | 5 | 290 | 8 |
| 30 | 20 | 120 | 20 | 210 | 3 | 300 | 12 |
| 40 | 20 | 130 | 20 | 220 | 1 | 310 | 16 |
| 50 | 20 | 140 | 20 | 230 | 0 | 320 | 20 |
| 60 | 20 | 150 | 20 | 240 | 0 | 330 | 20 |
| 70 | 20 | 160 | 20 | 250 | 0 | 340 | 20 |
| 80 | 20 | 170 | 18 | 260 | 1 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 23 | 90 | 6 | 180 | 8 | 270 | 21 |
| 10 | 21 | 100 | 4 | 190 | 11 | 280 | 23 |
| 20 | 21 | 110 | 2 | 200 | 18 | 290 | 24 |
| 30 | 21 | 120 | 1 | 210 | 23 | 300 | 25 |
| 40 | 25 | 130 | 0 | 220 | 25 | 310 | 23 |
| 50 | 23 | 140 | 0 | 230 | 23 | 320 | 22 |
| 60 | 20 | 150 | 1 | 240 | 22 | 330 | 22 |
| 70 | 15 | 160 | 3 | 250 | 21 | 340 | 23 |
| 80 | 10 | 170 | 5 | 260 | 21 | 350 | 24 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 7 | 90 | 3 | 180 | 18 | 270 | 2 |
| 10 | 6 | 100 | 5 | 190 | 18 | 280 | 1 |
| 20 | 4 | 110 | 8 | 200 | 20 | 290 | 0 |
| 30 | 2 | 120 | 13 | 210 | 20 | 300 | 0 |
| 40 | 1 | 130 | 19 | 220 | 18 | 310 | 1 |
| 50 | 0 | 140 | 22 | 230 | 13 | 320 | 2 |
| 60 | 0 | 150 | 22 | 240 | 8 | 330 | 5 |
| 70 | 1 | 160 | 20 | 250 | 5 | 340 | 7 |
| 80 | 2 | 170 | 18 | 260 | 3 | 350 | 7 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 1 | 180 | 5 | 270 | 10 |
| 10 | 20 | 100 | 1 | 190 | 2 | 280 | 15 |
| 20 | 20 | 110 | 0 | 200 | 0 | 290 | 20 |
| 30 | 18 | 120 | 1 | 210 | 0 | 300 | 20 |
| 40 | 12 | 130 | 4 | 220 | 1 | 310 | 20 |
| 50 | 9 | 140 | 5 | 230 | 2 | 320 | 20 |
| 60 | 7 | 150 | 2 | 240 | 4 | 330 | 20 |
| 70 | 5 | 160 | 1 | 250 | 6 | 340 | 20 |
| 80 | 3 | 170 | 2 | 260 | 8 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 10 | 90 | 20 | 180 | 2 | 270 | 3 |
| 10 | 15 | 100 | 20 | 190 | 1 | 280 | 2 |
| 20 | 20 | 110 | 20 | 200 | 0 | 290 | 1 |
| 30 | 20 | 120 | 20 | 210 | 1 | 300 | 0 |
| 40 | 20 | 130 | 18 | 220 | 2 | 310 | 0 |
| 50 | 20 | 140 | 12 | 230 | 3 | 320 | 2 |
| 60 | 20 | 150 | 9 | 240 | 2 | 330 | 3 |
| 70 | 20 | 160 | 5 | 250 | 1 | 340 | 5 |
| 80 | 20 | 170 | 3 | 260 | 2 | 350 | 7 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 0 | 180 | 20 | 270 | 20 |
| 10 | 18 | 100 | 1 | 190 | 20 | 280 | 20 |
| 20 | 11 | 110 | 3 | 200 | 20 | 290 | 20 |
| 30 | 7 | 120 | 4 | 210 | 20 | 300 | 20 |
| 40 | 5 | 130 | 7 | 220 | 20 | 310 | 20 |
| 50 | 3 | 140 | 10 | 230 | 20 | 320 | 20 |
| 60 | 1 | 150 | 15 | 240 | 20 | 330 | 20 |
| 70 | 0 | 160 | 20 | 250 | 20 | 340 | 20 |
| 80 | 0 | 170 | 20 | 260 | 20 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 7 | 90 | 18 | 180 | 10 | 270 | 3 |
| 10 | 10 | 100 | 20 | 190 | 7 | 280 | 3 |
| 20 | 16 | 110 | 22 | 200 | 6 | 290 | 2 |
| 30 | 20 | 120 | 20 | 210 | 5 | 300 | 1 |
| 40 | 22 | 130 | 20 | 220 | 6 | 310 | 0 |
| 50 | 22 | 140 | 20 | 230 | 7 | 320 | 0 |
| 60 | 22 | 150 | 20 | 240 | 6 | 330 | 1 |
| 70 | 22 | 160 | 18 | 250 | 4 | 340 | 3 |
| 80 | 19 | 170 | 14 | 260 | 2 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 25 | 90 | 22 | 180 | 10 | 270 | 3 |
| 10 | 22 | 100 | 22 | 190 | 8 | 280 | 5 |
| 20 | 22 | 110 | 22 | 200 | 5 | 290 | 8 |
| 30 | 22 | 120 | 25 | 210 | 3 | 300 | 10 |
| 40 | 25 | 130 | 22 | 220 | 2 | 310 | 15 |
| 50 | 25 | 140 | 22 | 230 | 0 | 320 | 18 |
| 60 | 25 | 150 | 18 | 240 | 0 | 330 | 22 |
| 70 | 25 | 160 | 15 | 250 | 0 | 340 | 22 |
| 80 | 23 | 170 | 12 | 260 | 1 | 350 | 25 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 20 | 180 | 20 | 270 | 0 |
| 10 | 0 | 100 | 20 | 190 | 16 | 280 | 1 |
| 20 | 1 | 110 | 20 | 200 | 13 | 290 | 3 |
| 30 | 2 | 120 | 20 | 210 | 9 | 300 | 3 |
| 40 | 4 | 130 | 19 | 220 | 6 | 310 | 3 |
| 50 | 7 | 140 | 19 | 230 | 4 | 320 | 2 |
| 60 | 10 | 150 | 20 | 240 | 2 | 330 | 3 |
| 70 | 15 | 160 | 20 | 250 | 1 | 340 | 2 |
| 80 | 18 | 170 | 20 | 260 | 0 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 5 | 90 | 24 | 180 | 24 | 270 | 7 |
| 10 | 7 | 100 | 24 | 190 | 24 | 280 | 5 |
| 20 | 10 | 110 | 24 | 200 | 30 | 290 | 3 |
| 30 | 13 | 120 | 25 | 210 | 30 | 300 | 1 |
| 40 | 14 | 130 | 30 | 220 | 25 | 310 | 0 |
| 50 | 18 | 140 | 30 | 230 | 18 | 320 | 0 |
| 60 | 25 | 150 | 30 | 240 | 14 | 330 | 0 |
| 70 | 30 | 160 | 25 | 250 | 13 | 340 | 1 |
| 80 | 27 | 170 | 24 | 260 | 10 | 350 | 3 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 25 | 180 | 12 | 270 | 1 |
| 10 | 25 | 100 | 25 | 190 | 10 | 280 | 2 |
| 20 | 25 | 110 | 25 | 200 | 7 | 290 | 4 |
| 30 | 25 | 120 | 25 | 210 | 5 | 300 | 5 |
| 40 | 25 | 130 | 25 | 220 | 4 | 310 | 7 |
| 50 | 25 | 140 | 25 | 230 | 2 | 320 | 10 |
| 60 | 25 | 150 | 22 | 240 | 1 | 330 | 12 |
| 70 | 25 | 160 | 18 | 250 | 0 | 340 | 15 |
| 80 | 25 | 170 | 15 | 260 | 0 | 350 | 18 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 25 | 180 | 25 | 270 | 10 |
| 10 | 5 | 100 | 25 | 190 | 25 | 280 | 7 |
| 20 | 7 | 110 | 25 | 200 | 25 | 290 | 5 |
| 30 | 10 | 120 | 25 | 210 | 25 | 300 | 3 |
| 40 | 16 | 130 | 25 | 220 | 25 | 310 | 1 |
| 50 | 19 | 140 | 25 | 230 | 25 | 320 | 0 |
| 60 | 20 | 150 | 25 | 240 | 20 | 330 | 0 |
| 70 | 25 | 160 | 25 | 250 | 19 | 340 | 0 |
| 80 | 25 | 170 | 25 | 260 | 16 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 4 | 180 | 4 | 270 | 1 |
| 10 | 0 | 100 | 3 | 190 | 5 | 280 | 2 |
| 20 | 0 | 110 | 2 | 200 | 6 | 290 | 4 |
| 30 | 1 | 120 | 1 | 210 | 7 | 300 | 5 |
| 40 | 3 | 130 | 1 | 220 | 5 | 310 | 5 |
| 50 | 5 | 140 | 1 | 230 | 2 | 320 | 5 |
| 60 | 8 | 150 | 1 | 240 | 1 | 330 | 4 |
| 70 | 7 | 160 | 2 | 250 | 0 | 340 | 3 |
| 80 | 5 | 170 | 3 | 260 | 0 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 20 | 180 | 25 | 270 | 2 |
| 10 | 1 | 100 | 23 | 190 | 20 | 280 | 3 |
| 20 | 2 | 110 | 25 | 200 | 18 | 290 | 4 |
| 30 | 3 | 120 | 25 | 210 | 14 | 300 | 3 |
| 40 | 6 | 130 | 25 | 220 | 10 | 310 | 1 |
| 50 | 8 | 140 | 20 | 230 | 8 | 320 | 0 |
| 60 | 10 | 150 | 25 | 240 | 6 | 330 | 1 |
| 70 | 14 | 160 | 25 | 250 | 4 | 340 | 3 |
| 80 | 18 | 170 | 25 | 260 | 3 | 350 | 4 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 22 | 180 | 30 | 270 | 0 |
| 10 | 25 | 100 | 22 | 190 | 22 | 280 | 0 |
| 20 | 30 | 110 | 22 | 200 | 20 | 290 | 0 |
| 30 | 25 | 120 | 24 | 210 | 16 | 300 | 1 |
| 40 | 25 | 130 | 25 | 220 | 10 | 310 | 3 |
| 50 | 25 | 140 | 30 | 230 | 8 | 320 | 5 |
| 60 | 25 | 150 | 25 | 240 | 5 | 330 | 8 |
| 70 | 30 | 160 | 25 | 250 | 3 | 340 | 10 |
| 80 | 30 | 170 | 25 | 260 | 1 | 350 | 17 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 18 | 90 | 0 | 180 | 20 | 270 | 0 |
| 10 | 18 | 100 | 0 | 190 | 20 | 280 | 0 |
| 20 | 16 | 110 | 1 | 200 | 20 | 290 | 1 |
| 30 | 14 | 120 | 3 | 210 | 20 | 300 | 2 |
| 40 | 10 | 130 | 6 | 220 | 13 | 310 | 3 |
| 50 | 6 | 140 | 8 | 230 | 8 | 320 | 6 |
| 60 | 3 | 150 | 13 | 240 | 6 | 330 | 9 |
| 70 | 2 | 160 | 18 | 250 | 3 | 340 | 14 |
| 80 | 1 | 170 | 20 | 260 | 1 | 350 | 16 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 1 | 180 | 17 | 270 | 20 |
| 10 | 0 | 100 | 0 | 190 | 20 | 280 | 20 |
| 20 | 0 | 110 | 0 | 200 | 20 | 290 | 19 |
| 30 | 1 | 120 | 1 | 210 | 20 | 300 | 18 |
| 40 | 2 | 130 | 2 | 220 | 20 | 310 | 15 |
| 50 | 2 | 140 | 3 | 230 | 20 | 320 | 10 |
| 60 | 1 | 150 | 5 | 240 | 20 | 330 | 7 |
| 70 | 1 | 160 | 8 | 250 | 20 | 340 | 4 |
| 80 | 1 | 170 | 12 | 260 | 20 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 10 | 90 | 20 | 180 | 20 | 270 | 4 |
| 10 | 13 | 100 | 20 | 190 | 20 | 280 | 2 |
| 20 | 18 | 110 | 20 | 200 | 20 | 290 | 1 |
| 30 | 20 | 120 | 20 | 210 | 20 | 300 | 0 |
| 40 | 20 | 130 | 20 | 220 | 20 | 310 | 0 |
| 50 | 20 | 140 | 20 | 230 | 18 | 320 | 1 |
| 60 | 20 | 150 | 20 | 240 | 13 | 330 | 2 |
| 70 | 20 | 160 | 20 | 250 | 10 | 340 | 4 |
| 80 | 20 | 170 | 20 | 260 | 7 | 350 | 7 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 7 | 90 | 20 | 180 | 6 | 270 | 0 |
| 10 | 9 | 100 | 20 | 190 | 5 | 280 | 1 |
| 20 | 11 | 110 | 20 | 200 | 3 | 290 | 2 |
| 30 | 15 | 120 | 20 | 210 | 2 | 300 | 2 |
| 40 | 16 | 130 | 18 | 220 | 1 | 310 | 0 |
| 50 | 18 | 140 | 17 | 230 | 1 | 320 | 0 |
| 60 | 20 | 150 | 15 | 240 | 2 | 330 | 1 |
| 70 | 20 | 160 | 11 | 250 | 2 | 340 | 3 |
| 80 | 20 | 170 | 9 | 260 | 1 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 21 | 180 | 25 | 270 | 9 |
| 10 | 1 | 100 | 22 | 190 | 23 | 280 | 8 |
| 20 | 3 | 110 | 22 | 200 | 20 | 290 | 7 |
| 30 | 5 | 120 | 25 | 210 | 15 | 300 | 7 |
| 40 | 8 | 130 | 22 | 220 | 11 | 310 | 8 |
| 50 | 11 | 140 | 23 | 230 | 8 | 320 | 7 |
| 60 | 15 | 150 | 23 | 240 | 7 | 330 | 4 |
| 70 | 18 | 160 | 22 | 250 | 7 | 340 | 2 |
| 80 | 20 | 170 | 25 | 260 | 8 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 0 | 180 | 0 | 270 | 19 |
| 10 | 19 | 100 | 0 | 190 | 0 | 280 | 19 |
| 20 | 17 | 110 | 1 | 200 | 1 | 290 | 20 |
| 30 | 14 | 120 | 2 | 210 | 2 | 300 | 23 |
| 40 | 9 | 130 | 1 | 220 | 3 | 310 | 20 |
| 50 | 5 | 140 | 0 | 230 | 5 | 320 | 19 |
| 60 | 3 | 150 | 0 | 240 | 8 | 330 | 20 |
| 70 | 2 | 160 | 1 | 250 | 14 | 340 | 25 |
| 80 | 1 | 170 | 1 | 260 | 18 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 4 | 180 | 8 | 270 | 6 |
| 10 | 1 | 100 | 3 | 190 | 7 | 280 | 7 |
| 20 | 2 | 110 | 3 | 200 | 6 | 290 | 6 |
| 30 | 4 | 120 | 4 | 210 | 5 | 300 | 5 |
| 40 | 5 | 130 | 4 | 220 | 4 | 310 | 4 |
| 50 | 5 | 140 | 6 | 230 | 3 | 320 | 3 |
| 60 | 6 | 150 | 7 | 240 | 3 | 330 | 1 |
| 70 | 6 | 160 | 8 | 250 | 4 | 340 | 0 |
| 80 | 5 | 170 | 8 | 260 | 5 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 22 | 270 | 0 |
| 10 | 22 | 100 | 19 | 190 | 22 | 280 | 0 |
| 20 | 22 | 110 | 20 | 200 | 19 | 290 | 0 |
| 30 | 22 | 120 | 22 | 210 | 15 | 300 | 1 |
| 40 | 22 | 130 | 22 | 220 | 10 | 310 | 3 |
| 50 | 22 | 140 | 22 | 230 | 7 | 320 | 5 |
| 60 | 22 | 150 | 22 | 240 | 5 | 330 | 7 |
| 70 | 22 | 160 | 22 | 250 | 3 | 340 | 10 |
| 80 | 22 | 170 | 22 | 260 | 1 | 350 | 15 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 16 | 180 | 22 | 270 | 23 |
| 10 | 0 | 100 | 20 | 190 | 21 | 280 | 22 |
| 20 | 0 | 110 | 23 | 200 | 21 | 290 | 20 |
| 30 | 1 | 120 | 25 | 210 | 25 | 300 | 16 |
| 40 | 2 | 130 | 25 | 220 | 23 | 310 | 13 |
| 50 | 4 | 140 | 23 | 230 | 22 | 320 | 9 |
| 60 | 7 | 150 | 22 | 240 | 22 | 330 | 7 |
| 70 | 9 | 160 | 22 | 250 | 22 | 340 | 4 |
| 80 | 13 | 170 | 23 | 260 | 25 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 25 | 90 | 24 | 180 | 20 | 270 | 0 |
| 10 | 24 | 100 | 24 | 190 | 17 | 280 | 1 |
| 20 | 23 | 110 | 23 | 200 | 12 | 290 | 3 |
| 30 | 22 | 120 | 23 | 210 | 8 | 300 | 5 |
| 40 | 21 | 130 | 22 | 220 | 5 | 310 | 8 |
| 50 | 23 | 140 | 23 | 230 | 3 | 320 | 12 |
| 60 | 24 | 150 | 24 | 240 | 1 | 330 | 17 |
| 70 | 24 | 160 | 27 | 250 | 0 | 340 | 20 |
| 80 | 23 | 170 | 23 | 260 | 0 | 350 | 23 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 19 | 180 | 20 | 270 | 19 |
| 10 | 0 | 100 | 20 | 190 | 20 | 280 | 16 |
| 20 | 1 | 110 | 20 | 200 | 20 | 290 | 14 |
| 30 | 3 | 120 | 20 | 210 | 20 | 300 | 10 |
| 40 | 5 | 130 | 20 | 220 | 20 | 310 | 7 |
| 50 | 7 | 140 | 20 | 230 | 20 | 320 | 5 |
| 60 | 10 | 150 | 20 | 240 | 20 | 330 | 3 |
| 70 | 13 | 160 | 20 | 250 | 20 | 340 | 1 |
| 80 | 16 | 170 | 20 | 260 | 20 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 2 | 90 | 2 | 180 | 22 | 270 | 12 |
| 10 | 1 | 100 | 4 | 190 | 22 | 280 | 9 |
| 20 | 0 | 110 | 7 | 200 | 22 | 290 | 7 |
| 30 | 1 | 120 | 9 | 210 | 22 | 300 | 4 |
| 40 | 2 | 130 | 12 | 220 | 22 | 310 | 2 |
| 50 | 2 | 140 | 18 | 230 | 22 | 320 | 1 |
| 60 | 1 | 150 | 22 | 240 | 22 | 330 | 0 |
| 70 | 0 | 160 | 22 | 250 | 22 | 340 | 1 |
| 80 | 1 | 170 | 22 | 260 | 18 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 2 | 180 | 17 | 270 | 25 |
| 10 | 1 | 100 | 1 | 190 | 19 | 280 | 23 |
| 20 | 0 | 110 | 0 | 200 | 19 | 290 | 20 |
| 30 | 1 | 120 | 1 | 210 | 19 | 300 | 20 |
| 40 | 1 | 130 | 2 | 220 | 18 | 310 | 18 |
| 50 | 1 | 140 | 5 | 230 | 22 | 320 | 15 |
| 60 | 0 | 150 | 7 | 240 | 22 | 330 | 10 |
| 70 | 0 | 160 | 10 | 250 | 21 | 340 | 8 |
| 80 | 1 | 170 | 14 | 260 | 25 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 1 | 180 | 15 | 270 | 7 |
| 10 | 4 | 100 | 0 | 190 | 20 | 280 | 5 |
| 20 | 4 | 110 | 0 | 200 | 19 | 290 | 3 |
| 30 | 3 | 120 | 1 | 210 | 18 | 300 | 2 |
| 40 | 3 | 130 | 2 | 220 | 18 | 310 | 1 |
| 50 | 4 | 140 | 3 | 230 | 20 | 320 | 0 |
| 60 | 5 | 150 | 5 | 240 | 20 | 330 | 0 |
| 70 | 4 | 160 | 7 | 250 | 15 | 340 | 1 |
| 80 | 2 | 170 | 10 | 260 | 10 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 19 | 90 | 0 | 180 | 9 | 270 | 15 |
| 10 | 18 | 100 | 0 | 190 | 10 | 280 | 16 |
| 20 | 13 | 110 | 1 | 200 | 8 | 290 | 18 |
| 30 | 9 | 120 | 3 | 210 | 6 | 300 | 22 |
| 40 | 6 | 130 | 7 | 220 | 5 | 310 | 23 |
| 50 | 4 | 140 | 10 | 230 | 6 | 320 | 20 |
| 60 | 2 | 150 | 11 | 240 | 8 | 330 | 20 |
| 70 | 1 | 160 | 9 | 250 | 10 | 340 | 22 |
| 80 | 0 | 170 | 9 | 260 | 14 | 350 | 19 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 11 | 180 | 2 | 270 | 23 |
| 10 | 15 | 100 | 8 | 190 | 3 | 280 | 21 |
| 20 | 13 | 110 | 6 | 200 | 6 | 290 | 20 |
| 30 | 11 | 120 | 4 | 210 | 10 | 300 | 20 |
| 40 | 10 | 130 | 3 | 220 | 12 | 310 | 21 |
| 50 | 10 | 140 | 1 | 230 | 18 | 320 | 23 |
| 60 | 10 | 150 | 0 | 240 | 23 | 330 | 23 |
| 70 | 11 | 160 | 0 | 250 | 23 | 340 | 23 |
| 80 | 12 | 170 | 1 | 260 | 24 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 19 | 90 | 0 | 180 | 20 | 270 | 22 |
| 10 | 18 | 100 | 1 | 190 | 22 | 280 | 22 |
| 20 | 12 | 110 | 2 | 200 | 22 | 290 | 22 |
| 30 | 10 | 120 | 4 | 210 | 22 | 300 | 22 |
| 40 | 6 | 130 | 6 | 220 | 22 | 310 | 22 |
| 50 | 4 | 140 | 9 | 230 | 22 | 320 | 22 |
| 60 | 2 | 150 | 13 | 240 | 22 | 330 | 22 |
| 70 | 1 | 160 | 17 | 250 | 22 | 340 | 21 |
| 80 | 0 | 170 | 19 | 260 | 22 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 16 | 90 | 2 | 180 | 25 | 270 | 24 |
| 10 | 13 | 100 | 3 | 190 | 23 | 280 | 23 |
| 20 | 8 | 110 | 5 | 200 | 21 | 290 | 21 |
| 30 | 5 | 120 | 8 | 210 | 21 | 300 | 21 |
| 40 | 3 | 130 | 12 | 220 | 23 | 310 | 23 |
| 50 | 2 | 140 | 17 | 230 | 24 | 320 | 24 |
| 60 | 1 | 150 | 20 | 240 | 23 | 330 | 25 |
| 70 | 0 | 160 | 22 | 250 | 22 | 340 | 25 |
| 80 | 1 | 170 | 23 | 260 | 23 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 7 | 90 | 0 | 180 | 6 | 270 | 21 |
| 10 | 5 | 100 | 0 | 190 | 8 | 280 | 22 |
| 20 | 3 | 110 | 1 | 200 | 11 | 290 | 25 |
| 30 | 2 | 120 | 1 | 210 | 15 | 300 | 20 |
| 40 | 1 | 130 | 1 | 220 | 17 | 310 | 20 |
| 50 | 1 | 140 | 1 | 230 | 19 | 320 | 19 |
| 60 | 1 | 150 | 1 | 240 | 19 | 330 | 18 |
| 70 | 2 | 160 | 2 | 250 | 21 | 340 | 15 |
| 80 | 1 | 170 | 4 | 260 | 22 | 350 | 10 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 4 | 90 | 21 | 180 | 20 | 270 | 1 |
| 10 | 3 | 100 | 23 | 190 | 17 | 280 | 2 |
| 20 | 3 | 110 | 25 | 200 | 11 | 290 | 4 |
| 30 | 4 | 120 | 23 | 210 | 7 | 300 | 5 |
| 40 | 5 | 130 | 20 | 220 | 4 | 310 | 7 |
| 50 | 6 | 140 | 19 | 230 | 2 | 320 | 8 |
| 60 | 8 | 150 | 20 | 240 | 1 | 330 | 8 |
| 70 | 13 | 160 | 22 | 250 | 0 | 340 | 7 |
| 80 | 18 | 170 | 23 | 260 | 0 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 9 | 90 | 21 | 180 | 3 | 270 | 1 |
| 10 | 12 | 100 | 15 | 190 | 1 | 280 | 2 |
| 20 | 17 | 110 | 22 | 200 | 0 | 290 | 2 |
| 30 | 20 | 120 | 20 | 210 | 0 | 300 | 1 |
| 40 | 20 | 130 | 19 | 220 | 1 | 310 | 0 |
| 50 | 23 | 140 | 16 | 230 | 2 | 320 | 1 |
| 60 | 34 | 150 | 12 | 240 | 3 | 330 | 2 |
| 70 | 21 | 160 | 8 | 250 | 2 | 340 | 3 |
| 80 | 18 | 170 | 5 | 260 | 0 | 350 | 6 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 21 | 90 | 0 | 180 | 21 | 270 | 20 |
| 10 | 19 | 100 | 0 | 190 | 23 | 280 | 20 |
| 20 | 15 | 110 | 1 | 200 | 23 | 290 | 22 |
| 30 | 10 | 120 | 3 | 210 | 23 | 300 | 23 |
| 40 | 7 | 130 | 4 | 220 | 23 | 310 | 23 |
| 50 | 4 | 140 | 7 | 230 | 23 | 320 | 23 |
| 60 | 3 | 150 | 10 | 240 | 23 | 330 | 23 |
| 70 | 1 | 160 | 15 | 250 | 22 | 340 | 23 |
| 80 | 0 | 170 | 19 | 260 | 20 | 350 | 22 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 0 | 180 | 20 | 270 | 13 |
| 10 | 20 | 100 | 0 | 190 | 20 | 280 | 13 |
| 20 | 20 | 110 | 0 | 200 | 20 | 290 | 14 |
| 30 | 18 | 120 | 1 | 210 | 20 | 300 | 14 |
| 40 | 12 | 130 | 3 | 220 | 20 | 310 | 16 |
| 50 | 8 | 140 | 5 | 230 | 20 | 320 | 20 |
| 60 | 5 | 150 | 8 | 240 | 18 | 330 | 20 |
| 70 | 3 | 160 | 11 | 250 | 14 | 340 | 20 |
| 80 | 1 | 170 | 18 | 260 | 13 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 7 | 90 | 5 | 180 | 10 | 270 | 12 |
| 10 | 4 | 100 | 7 | 190 | 8 | 280 | 17 |
| 20 | 3 | 110 | 10 | 200 | 6 | 290 | 18 |
| 30 | 1 | 120 | 14 | 210 | 6 | 300 | 20 |
| 40 | 0 | 130 | 13 | 220 | 5 | 310 | 20 |
| 50 | 0 | 140 | 14 | 230 | 6 | 320 | 20 |
| 60 | 0 | 150 | 20 | 240 | 7 | 330 | 20 |
| 70 | 1 | 160 | 18 | 250 | 8 | 340 | 16 |
| 80 | 3 | 170 | 14 | 260 | 8 | 350 | 12 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 2 | 90 | 20 | 180 | 20 | 270 | 15 |
| 10 | 4 | 100 | 20 | 190 | 20 | 280 | 10 |
| 20 | 6 | 110 | 20 | 200 | 20 | 290 | 6 |
| 30 | 10 | 120 | 20 | 210 | 20 | 300 | 4 |
| 40 | 15 | 130 | 20 | 220 | 20 | 310 | 2 |
| 50 | 19 | 140 | 20 | 230 | 20 | 320 | 1 |
| 60 | 20 | 150 | 20 | 240 | 20 | 330 | 0 |
| 70 | 20 | 160 | 20 | 250 | 20 | 340 | 0 |
| 80 | 20 | 170 | 20 | 260 | 19 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 9 | 90 | 18 | 180 | 12 | 270 | 0 |
| 10 | 12 | 100 | 16 | 190 | 13 | 280 | 0 |
| 20 | 14 | 110 | 16 | 200 | 13 | 290 | 1 |
| 30 | 13 | 120 | 20 | 210 | 9 | 300 | 1 |
| 40 | 10 | 130 | 14 | 220 | 5 | 310 | 1 |
| 50 | 9 | 140 | 9 | 230 | 2 | 320 | 1 |
| 60 | 9 | 150 | 9 | 240 | 1 | 330 | 2 |
| 70 | 9 | 160 | 9 | 250 | 0 | 340 | 3 |
| 80 | 15 | 170 | 10 | 260 | 0 | 350 | 6 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 5 | 90 | 5 | 180 | 1 | 270 | 1 |
| 10 | 5 | 100 | 5 | 190 | 2 | 280 | 2 |
| 20 | 6 | 110 | 5 | 200 | 2 | 290 | 4 |
| 30 | 7 | 120 | 4 | 210 | 1 | 300 | 4 |
| 40 | 8 | 130 | 4 | 220 | 0 | 310 | 4 |
| 50 | 7 | 140 | 5 | 230 | 1 | 320 | 4 |
| 60 | 6 | 150 | 4 | 240 | 2 | 330 | 5 |
| 70 | 5 | 160 | 2 | 250 | 2 | 340 | 5 |
| 80 | 5 | 170 | 1 | 260 | 1 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 6 | 90 | 20 | 180 | 20 | 270 | 6 |
| 10 | 9 | 100 | 20 | 190 | 20 | 280 | 4 |
| 20 | 14 | 110 | 20 | 200 | 20 | 290 | 2 |
| 30 | 18 | 120 | 20 | 210 | 20 | 300 | 1 |
| 40 | 20 | 130 | 20 | 220 | 20 | 310 | 0 |
| 50 | 20 | 140 | 20 | 230 | 20 | 320 | 0 |
| 60 | 20 | 150 | 20 | 240 | 20 | 330 | 1 |
| 70 | 20 | 160 | 20 | 250 | 14 | 340 | 2 |
| 80 | 20 | 170 | 20 | 260 | 9 | 350 | 4 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 12 | 180 | 23 | 270 | 21 |
| 10 | 1 | 100 | 18 | 190 | 25 | 280 | 21 |
| 20 | 0 | 110 | 22 | 200 | 23 | 290 | 23 |
| 30 | 0 | 120 | 23 | 210 | 22 | 300 | 22 |
| 40 | 0 | 130 | 21 | 220 | 23 | 310 | 20 |
| 50 | 1 | 140 | 21 | 230 | 25 | 320 | 18 |
| 60 | 3 | 150 | 21 | 240 | 23 | 330 | 12 |
| 70 | 5 | 160 | 21 | 250 | 22 | 340 | 8 |
| 80 | 8 | 170 | 21 | 260 | 21 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 19 | 90 | 20 | 180 | 1 | 270 | 0 |
| 10 | 19 | 100 | 18 | 190 | 1 | 280 | 0 |
| 20 | 20 | 110 | 15 | 200 | 2 | 290 | 2 |
| 30 | 20 | 120 | 10 | 210 | 1 | 300 | 4 |
| 40 | 20 | 130 | 9 | 220 | 0 | 310 | 6 |
| 50 | 20 | 140 | 6 | 230 | 0 | 320 | 9 |
| 60 | 20 | 150 | 3 | 240 | 1 | 330 | 14 |
| 70 | 20 | 160 | 2 | 250 | 1 | 340 | 16 |
| 80 | 20 | 170 | 1 | 260 | 1 | 350 | 19 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 19 | 180 | 25 | 270 | 22 |
| 10 | 0 | 100 | 20 | 190 | 25 | 280 | 20 |
| 20 | 0 | 110 | 25 | 200 | 25 | 290 | 19 |
| 30 | 2 | 120 | 25 | 210 | 25 | 300 | 15 |
| 40 | 3 | 130 | 25 | 220 | 25 | 310 | 10 |
| 50 | 5 | 140 | 25 | 230 | 25 | 320 | 8 |
| 60 | 8 | 150 | 25 | 240 | 25 | 330 | 5 |
| 70 | 10 | 160 | 25 | 250 | 25 | 340 | 3 |
| 80 | 15 | 170 | 25 | 260 | 25 | 350 | 2 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 17 | 90 | 0 | 180 | 0 | 270 | 19 |
| 10 | 17 | 100 | 1 | 190 | 0 | 280 | 19 |
| 20 | 16 | 110 | 2 | 200 | 1 | 290 | 19 |
| 30 | 12 | 120 | 2 | 210 | 2 | 300 | 22 |
| 40 | 9 | 130 | 1 | 220 | 5 | 310 | 21 |
| 50 | 6 | 140 | 1 | 230 | 7 | 320 | 19 |
| 60 | 3 | 150 | 1 | 240 | 10 | 330 | 19 |
| 70 | 2 | 160 | 2 | 250 | 15 | 340 | 20 |
| 80 | 1 | 170 | 1 | 260 | 18 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 19 | 90 | 20 | 180 | 0 | 270 | 0 |
| 10 | 20 | 100 | 18 | 190 | 1 | 280 | 0 |
| 20 | 23 | 110 | 14 | 200 | 2 | 290 | 1 |
| 30 | 20 | 120 | 12 | 210 | 1 | 300 | 3 |
| 40 | 17 | 130 | 8 | 220 | 0 | 310 | 5 |
| 50 | 17 | 140 | 5 | 230 | 0 | 320 | 8 |
| 60 | 20 | 150 | 3 | 240 | 1 | 330 | 11 |
| 70 | 23 | 160 | 1 | 250 | 2 | 340 | 15 |
| 80 | 21 | 170 | 0 | 260 | 1 | 350 | 18 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 22 | 90 | 0 | 180 | 20 | 270 | 24 |
| 10 | 20 | 100 | 1 | 190 | 25 | 280 | 26 |
| 20 | 16 | 110 | 2 | 200 | 26 | 290 | 28 |
| 30 | 10 | 120 | 5 | 210 | 28 | 300 | 23 |
| 40 | 7 | 130 | 8 | 220 | 25 | 310 | 22 |
| 50 | 4 | 140 | 9 | 230 | 25 | 320 | 21 |
| 60 | 2 | 150 | 15 | 240 | 24 | 330 | 22 |
| 70 | 1 | 160 | 20 | 250 | 25 | 340 | 23 |
| 80 | 0 | 170 | 19 | 260 | 28 | 350 | 24 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 2 | 180 | 10 | 270 | 19 |
| 10 | 2 | 100 | 4 | 190 | 14 | 280 | 23 |
| 20 | 0 | 110 | 6 | 200 | 17 | 290 | 20 |
| 30 | 0 | 120 | 4 | 210 | 18 | 300 | 18 |
| 40 | 1 | 130 | 3 | 220 | 20 | 310 | 16 |
| 50 | 2 | 140 | 3 | 230 | 25 | 320 | 15 |
| 60 | 2 | 150 | 4 | 240 | 23 | 330 | 10 |
| 70 | 1 | 160 | 6 | 250 | 19 | 340 | 8 |
| 80 | 1 | 170 | 8 | 260 | 18 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 2 | 90 | 6 | 180 | 8 | 270 | 3 |
| 10 | 3 | 100 | 8 | 190 | 7 | 280 | 3 |
| 20 | 3 | 110 | 10 | 200 | 6 | 290 | 5 |
| 30 | 3 | 120 | 16 | 210 | 5 | 300 | 6 |
| 40 | 1 | 130 | 20 | 220 | 4 | 310 | 5 |
| 50 | 0 | 140 | 20 | 230 | 4 | 320 | 4 |
| 60 | 0 | 150 | 20 | 240 | 5 | 330 | 5 |
| 70 | 1 | 160 | 20 | 250 | 6 | 340 | 5 |
| 80 | 3 | 170 | 12 | 260 | 5 | 350 | 3 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 15 | 180 | 22 | 270 | 22 |
| 10 | 0 | 100 | 20 | 190 | 21 | 280 | 22 |
| 20 | 0 | 110 | 22 | 200 | 21 | 290 | 21 |
| 30 | 0 | 120 | 22 | 210 | 22 | 300 | 20 |
| 40 | 1 | 130 | 22 | 220 | 22 | 310 | 15 |
| 50 | 3 | 140 | 22 | 230 | 22 | 320 | 11 |
| 60 | 5 | 150 | 22 | 240 | 22 | 330 | 8 |
| 70 | 8 | 160 | 22 | 250 | 22 | 340 | 5 |
| 80 | 11 | 170 | 22 | 260 | 22 | 350 | 3 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 10 | 90 | 5 | 180 | 9 | 270 | 16 |
| 10 | 9 | 100 | 2 | 190 | 9 | 280 | 19 |
| 20 | 9 | 110 | 1 | 200 | 8 | 290 | 17 |
| 30 | 8 | 120 | 0 | 210 | 8 | 300 | 14 |
| 40 | 8 | 130 | 0 | 220 | 8 | 310 | 14 |
| 50 | 8 | 140 | 1 | 230 | 9 | 320 | 16 |
| 60 | 8 | 150 | 3 | 240 | 10 | 330 | 20 |
| 70 | 8 | 160 | 5 | 250 | 10 | 340 | 18 |
| 80 | 7 | 170 | 8 | 260 | 12 | 350 | 13 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 28 | 180 | 18 | 270 | 1 |
| 10 | 1 | 100 | 25 | 190 | 11 | 280 | 2 |
| 20 | 3 | 110 | 20 | 200 | 7 | 290 | 1 |
| 30 | 5 | 120 | 18 | 210 | 5 | 300 | 1 |
| 40 | 7 | 130 | 19 | 220 | 3 | 310 | 1 |
| 50 | 11 | 140 | 22 | 230 | 1 | 320 | 2 |
| 60 | 18 | 150 | 28 | 240 | 0 | 330 | 1 |
| 70 | 30 | 160 | 25 | 250 | 0 | 340 | 0 |
| 80 | 25 | 170 | 30 | 260 | 0 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 8 | 90 | 0 | 180 | 8 | 270 | 15 |
| 10 | 8 | 100 | 0 | 190 | 8 | 280 | 13 |
| 20 | 8 | 110 | 1 | 200 | 9 | 290 | 14 |
| 30 | 8 | 120 | 2 | 210 | 10 | 300 | 18 |
| 40 | 8 | 130 | 4 | 220 | 10 | 310 | 20 |
| 50 | 7 | 140 | 6 | 230 | 11 | 320 | 16 |
| 60 | 5 | 150 | 9 | 240 | 13 | 330 | 11 |
| 70 | 3 | 160 | 10 | 250 | 17 | 340 | 10 |
| 80 | 1 | 170 | 9 | 260 | 18 | 350 | 9 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 18 | 90 | 2 | 180 | 21 | 270 | 22 |
| 10 | 14 | 100 | 4 | 190 | 20 | 280 | 22 |
| 20 | 8 | 110 | 6 | 200 | 20 | 290 | 22 |
| 30 | 5 | 120 | 10 | 210 | 18 | 300 | 23 |
| 40 | 3 | 130 | 15 | 220 | 17 | 310 | 23 |
| 50 | 1 | 140 | 20 | 230 | 17 | 320 | 22 |
| 60 | 0 | 150 | 22 | 240 | 18 | 330 | 20 |
| 70 | 0 | 160 | 21 | 250 | 19 | 340 | 20 |
| 80 | 1 | 170 | 21 | 260 | 20 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 9 | 180 | 19 | 270 | 8 |
| 10 | 0 | 100 | 12 | 190 | 19 | 280 | 6 |
| 20 | 1 | 110 | 16 | 200 | 25 | 290 | 4 |
| 30 | 2 | 120 | 18 | 210 | 20 | 300 | 3 |
| 40 | 1 | 130 | 20 | 220 | 18 | 310 | 1 |
| 50 | 1 | 140 | 18 | 230 | 20 | 320 | 1 |
| 60 | 3 | 150 | 20 | 240 | 20 | 330 | 1 |
| 70 | 4 | 160 | 22 | 250 | 18 | 340 | 1 |
| 80 | 7 | 170 | 22 | 260 | 13 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 20 | 90 | 20 | 180 | 6 | 270 | 6 |
| 10 | 20 | 100 | 20 | 190 | 4 | 280 | 9 |
| 20 | 20 | 110 | 20 | 200 | 2 | 290 | 15 |
| 30 | 20 | 120 | 20 | 210 | 1 | 300 | 18 |
| 40 | 20 | 130 | 20 | 220 | 0 | 310 | 20 |
| 50 | 20 | 140 | 20 | 230 | 0 | 320 | 20 |
| 60 | 20 | 150 | 18 | 240 | 1 | 330 | 20 |
| 70 | 20 | 160 | 14 | 250 | 2 | 340 | 20 |
| 80 | 20 | 170 | 10 | 260 | 4 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 7 | 90 | 20 | 180 | 20 | 270 | 5 |
| 10 | 11 | 100 | 20 | 190 | 20 | 280 | 3 |
| 20 | 14 | 110 | 20 | 200 | 20 | 290 | 1 |
| 30 | 20 | 120 | 20 | 210 | 20 | 300 | 0 |
| 40 | 20 | 130 | 20 | 220 | 20 | 310 | 0 |
| 50 | 20 | 140 | 20 | 230 | 20 | 320 | 0 |
| 60 | 20 | 150 | 20 | 240 | 14 | 330 | 1 |
| 70 | 20 | 160 | 20 | 250 | 11 | 340 | 3 |
| 80 | 20 | 170 | 20 | 260 | 7 | 350 | 5 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 10 | 90 | 2 | 180 | 5 | 270 | 16 |
| 10 | 8 | 100 | 5 | 190 | 4 | 280 | 19 |
| 20 | 4 | 110 | 8 | 200 | 4 | 290 | 24 |
| 30 | 2 | 120 | 11 | 210 | 5 | 300 | 24 |
| 40 | 1 | 130 | 11 | 220 | 7 | 310 | 24 |
| 50 | 0 | 140 | 11 | 230 | 8 | 320 | 25 |
| 60 | 0 | 150 | 12 | 240 | 11 | 330 | 21 |
| 70 | 0 | 160 | 10 | 250 | 15 | 340 | 17 |
| 80 | 1 | 170 | 8 | 260 | 16 | 350 | 15 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 2 | 90 | 15 | 180 | 23 | 270 | 3 |
| 10 | 0 | 100 | 20 | 190 | 21 | 280 | 4 |
| 20 | 0 | 110 | 23 | 200 | 18 | 290 | 5 |
| 30 | 0 | 120 | 25 | 210 | 12 | 300 | 7 |
| 40 | 1 | 130 | 23 | 220 | 10 | 310 | 8 |
| 50 | 2 | 140 | 20 | 230 | 7 | 320 | 7 |
| 60 | 4 | 150 | 18 | 240 | 5 | 330 | 6 |
| 70 | 7 | 160 | 19 | 250 | 4 | 340 | 5 |
| 80 | 10 | 170 | 23 | 260 | 3 | 350 | 4 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 2 | 90 | 17 | 180 | 22 | 270 | 22 |
| 10 | 1 | 100 | 20 | 190 | 22 | 280 | 24 |
| 20 | 0 | 110 | 25 | 200 | 22 | 290 | 24 |
| 30 | 0 | 120 | 25 | 210 | 22 | 300 | 22 |
| 40 | 1 | 130 | 22 | 220 | 22 | 310 | 19 |
| 50 | 2 | 140 | 22 | 230 | 22 | 320 | 16 |
| 60 | 5 | 150 | 22 | 240 | 22 | 330 | 10 |
| 70 | 7 | 160 | 22 | 250 | 22 | 340 | 7 |
| 80 | 11 | 170 | 22 | 260 | 22 | 350 | 4 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 15 | 90 | 18 | 180 | 7 | 270 | 6 |
| 10 | 20 | 100 | 15 | 190 | 4 | 280 | 8 |
| 20 | 23 | 110 | 13 | 200 | 2 | 290 | 10 |
| 30 | 18 | 120 | 12 | 210 | 1 | 300 | 10 |
| 40 | 16 | 130 | 11 | 220 | 0 | 310 | 10 |
| 50 | 16 | 140 | 11 | 230 | 0 | 320 | 10 |
| 60 | 17 | 150 | 11 | 240 | 1 | 330 | 10 |
| 70 | 20 | 160 | 10 | 250 | 2 | 340 | 11 |
| 80 | 22 | 170 | 9 | 260 | 4 | 350 | 14 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 3 | 90 | 4 | 180 | 0 | 270 | 4 |
| 10 | 4 | 100 | 5 | 190 | 1 | 280 | 4 |
| 20 | 5 | 110 | 6 | 200 | 2 | 290 | 5 |
| 30 | 4 | 120 | 4 | 210 | 2 | 300 | 4 |
| 40 | 2 | 130 | 1 | 220 | 0 | 310 | 2 |
| 50 | 2 | 140 | 0 | 230 | 1 | 320 | 2 |
| 60 | 3 | 150 | 1 | 240 | 3 | 330 | 3 |
| 70 | 5 | 160 | 1 | 250 | 5 | 340 | 5 |
| 80 | 4 | 170 | 1 | 260 | 5 | 350 | 4 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 1 | 90 | 20 | 180 | 18 | 270 | 1 |
| 10 | 3 | 100 | 20 | 190 | 11 | 280 | 1 |
| 20 | 5 | 110 | 20 | 200 | 8 | 290 | 0 |
| 30 | 8 | 120 | 20 | 210 | 5 | 300 | 0 |
| 40 | 11 | 130 | 20 | 220 | 3 | 310 | 1 |
| 50 | 16 | 140 | 20 | 230 | 1 | 320 | 1 |
| 60 | 20 | 150 | 20 | 240 | 1 | 330 | 1 |
| 70 | 20 | 160 | 20 | 250 | 0 | 340 | 0 |
| 80 | 20 | 170 | 20 | 260 | 1 | 350 | 0 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 15 | 90 | 1 | 180 | 20 | 270 | 20 |
| 10 | 10 | 100 | 3 | 190 | 20 | 280 | 20 |
| 20 | 8 | 110 | 5 | 200 | 20 | 290 | 20 |
| 30 | 5 | 120 | 8 | 210 | 20 | 300 | 20 |
| 40 | 3 | 130 | 10 | 220 | 20 | 310 | 20 |
| 50 | 1 | 140 | 18 | 230 | 20 | 320 | 20 |
| 60 | 0 | 150 | 20 | 240 | 20 | 330 | 20 |
| 70 | 0 | 160 | 20 | 250 | 20 | 340 | 20 |
| 80 | 0 | 170 | 20 | 260 | 20 | 350 | 20 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 4 | 90 | 1 | 180 | 20 | 270 | 5 |
| 10 | 5 | 100 | 2 | 190 | 13 | 280 | 4 |
| 20 | 6 | 110 | 4 | 200 | 8 | 290 | 3 |
| 30 | 7 | 120 | 6 | 210 | 6 | 300 | 4 |
| 40 | 5 | 130 | 9 | 220 | 5 | 310 | 5 |
| 50 | 3 | 140 | 12 | 230 | 4 | 320 | 4 |
| 60 | 1 | 150 | 18 | 240 | 4 | 330 | 4 |
| 70 | 0 | 160 | 20 | 250 | 5 | 340 | 4 |
| 80 | 0 | 170 | 20 | 260 | 6 | 350 | 4 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
| AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) | AZIMUT (degrés) | ATTÉNUATION (dB) (1) |
|---|---|---|---|---|---|---|---|
| 0 | 0 | 90 | 10 | 180 | 18 | 270 | 10 |
| 10 | 1 | 100 | 12 | 190 | 20 | 280 | 7 |
| 20 | 3 | 110 | 15 | 200 | 20 | 290 | 4 |
| 30 | 3 | 120 | 20 | 210 | 20 | 300 | 2 |
| 40 | 2 | 130 | 20 | 220 | 20 | 310 | 1 |
| 50 | 1 | 140 | 20 | 230 | 20 | 320 | 1 |
| 60 | 2 | 150 | 20 | 240 | 20 | 330 | 3 |
| 70 | 4 | 160 | 20 | 250 | 15 | 340 | 2 |
| 80 | 7 | 170 | 20 | 260 | 17 | 350 | 1 |
| (1) Atténuation par rapport à la PAR maximale. | |||||||
1 version